8 - 1Vpp Sine/Cosine output signals
NOTE
Sine/Cosine output signals are available for SSI (...BG1... order code) and BiSS
(...SC1... order code) models.
A (COSINE) and B (SINE) signals are to be intended with CW rotation as viewed
from the shaft side. They provide 256 sinusoidal waves per mechanical
revolution with amplitude 1Vpp. 1Vpp output level results from differential
signals detection. The frequency of output signals is proportional to the
rotational speed of the encoder.
8.1 Output signals voltage level
The voltage level refers to the differential value between normal and inverted
signal (differential).
Recommended input circuit
Encoder
Input circuit
MAN AMM36 SSI_BiSS_RS485 E 1.0.odt 8 - 1Vpp Sine/Cosine output signals 49 of 56