SPECIFICATIONS
GENERAL
External Supply ................................................ PSD5201 Intrinsically Safe Power Supply
NOTE1
Main Housing Ambient Temperature Range ................................................... -40°C to +85°C
Sensor Ambient Temperature Range .......................................................... -55°C to +110°C
Maximum Pipeline Surface Temperature .................................................................. +110°C
Typical minimum pig speed ............................................................................... 0.1m/s
NOTE2
Ingress Protection ..................................................................................................... IP66
ATEX code ...................................................................................................... II 1 G
IECEx code ................................................................................................ Ex ia IIB T4 Ga
EU Type Examination Certificate Number .................................................. EMT16ATEX0007X
IECEx Certificate Number ................................................................... IECEx EMT 16.0006X
Weight in Aluminium ................................................................................................... 8kg
Weight in Stainless Steel ........................................................................................... 13kg
OUTPUTS
Relay Outputs (Volt Free Contacts) ...................................................................... DPDT
NOTE3
Current Loop Output ....................................................................................... 4-20mA
NOTE4
Serial Data Interface ..................................................................................RS485 MODBUS
NOTE1
The ID5002P must be powered from a GM International PSD5201 power supply which
may be purchased separately from Online Electronics Ltd.
NOTE2
Minimum pig speed depends on pig type, pipeline configuration and installation
position.
NOTE3
DPDT is equivalent to 2x SPDT. Contact rating 30VDC @ 2A. Limited by certification
entity parameters.
NOTE4
Current Loop levels are configurable between 4mA and 20mA. Default set state
15.0mA. Default reset state 5.0mA. Tolerance ±1.0mA.