3.5.4.
SYSTEM MENU 1 – STATUS
This menu item consists of two status pages.
STATUS 1 shows if data LOGGING is ON or OFF, the number of events and relay configuration.
STATUS 2 shows the date, time and output delay setting. The STATUS screen can be halted
by pressing and holding the control button.
Ensure all of these settings are at the required values.
3.5.5.
SYSTEM MENU 1 - VIEW EVENTS
Selecting this item will allow the user to cycle through all logged EVENTs from newest to
oldest. The EVENT number, and EVENT date and time are shown. Pressing the CONTROL
BUTTON will cycle to the next event. The CONTROL BUTTON can be held to pause at any point.
If the COUNTDOWN INDICATOR reaches 0 then the unit will exit and resume LISTENING.
3.5.6.
SYSTEM MENU 1 – SET DETECT PARAMS
These items allow the user to configure the detection parameters. Refer to 3.4 DETECTION
ALGORITHM.
5
P A R A M E T E R S 1
E X I T
> U F B I N 1 0 0
L F B I N 0 0 1
N U M A V G S 4 0
M O R E . . .
MORE…
3
P A R A M E T E R S 2
E X I T
> A V N S E T I M E ( m ) 0 0 1
A V V A L T I M E ( s ) 0 0 5
H A R D W A R E G A I N 1
S E N S O R G A I N 1 0 0 0
M O R E . . .
MORE…
5
P A R A M E T E R S 3
E X I T
> H L S E T 0 2 0 0 0
L L S E T 0 1 7 0 0
F O R C E A N 0 0 0 0 0
M O R E . . .
MORE…
1
P A R A M E T E R S 4
E X I T
> D E L T A T I M E ( s ) 0 0 3
O U T P U T D E L A Y
M O R E . . .