ENGLISH
30 OPERATING THE MONITOR
Adjustment Item
Problem / Option Button to Press
Configuration1
Switch on state
Power off
The display will remain off when the power cord is
connected to a wall outlet.
Forced on
The display will turn on when the power cord is
connected to a wall outlet.
Last status
The display will return to the previous power status (on/
off/standby) when removing and replacing the power
cord.
Panel saving
Brightness
Brightness
is turned off.
For the display to slightly expand the image size and
shift the position of pixels in four directions (up, down,
left or right).
Off
On
The image brightness will be reduced to an
appropriate level.
Pixel shift
Off
Auto
0-80
Pixel shift
is turned off.
Move the position of the image
automatically.
Move the position of the image at set
intervals.
*
1
Only VGA input.
For best results, use the Auto Adjust in conjunction with the adjustment pattern.
See page 42 for SCREEN ADJUSTMENTS.
*
2
A temperature warning message will be shown on the screen if the internal temperature reaches
58°C. All key functions except power key will then be disabled. And once the temperature reaches
60°C, the monitor power will shut down automatically.
PIP
1
2
3
SET
MENU
1
:Move
:Select
Switch on state
Auto adjust
Power save
Panel svaing
Network controlport
Network settings
Factory reset
RS232
Last status
Configuration1 reset
Configuration 1
:Exit
Auto adjust*
1
Adjust Position, Clock and Clock Phase automatically.
Power save
Power save
is turned off.
Off
On
The monitor will turn to power save mode automatically after
10 seconds when no key is touched.
Cooling Fan*
2
Cooling Fan
is turned off.
Off
Auto
The fan turns on automatically when the
monitor's internal temperature reaches
45°C or higher.
It turns off automatically when the monitor's
internal temperature reaches 45°C or less.
Low
High
Medium
Fan speed 3500RPM
Fan speed 3800RPM
Fan speed 4000RPM