3.1  Diagnostic LEDs 

Each DVXi/ME Media-Extender is fitted with four indicator LEDs:

 Power, Video OK, Data Error, 

Link Status

: The 

Power

 LEDs are next to the Power socket.  

The location of the LEDs is shown below: 

 

 

 

 

 

 

 

 

Diagnostic - LEDs at DVXi/ME - Extender 

 

LED 

Appearance 

Diagnostics 

Power LED

 

(Red LED) 

Off 
On 

Device not ready 
Device ready 

Video Okay

 

(Green LED) 

Off 
On 

No or invalid video signal detected 
Device ready 

Link Status

 

(Green LED) 

blinking 
On 

No fibre connection 
Device ready 

Data Error

 

(Red LED) 

Off 
blinking / On 

Device ready 
Errors through data transmission over fibre Cable 
(Cable too long, too high attenuation or too much 
EMI interferences ) 

 

 

4  Audio/serial option 

No setting up or user adjustments are required. Please note that on the dual access model, the serial 
link is always active Please bear in mind that the Remote Unit’s serial port is wired as DTE (i.e. the 
same as that on a PC). To connect a serial printer (or other DTE rather than DCE device) to the 
Remote Unit, you will need a Null-Modem (crossover) cable between the Remote Unit and the 
printer. Select Xon/Xoff software flow control on the printer and PC. A serial Touchscreen may be 
plugged directly into the Remote Unit.

 

5  Troubleshooting 

Monitor 

There isn’t a picture. 

Check the power supply connection at the Local and Remote unit. Is the 

Power

 (Red 

LED) at the Local and Remote unit illuminated? If not, the internal power-supply may be 
damaged or there may be an internal error.  

Check that the Interconnection cable is connected at the Local Unit and the Remote Unit. 
Is the 

Link Status

 LED illuminated? If not, there may be a problem with the 

Interconnection cable: 

Are there 

Errors through data transmission over fibre Cable (Cable too long, too high 

attenuation or too much EMI interferences )? Is the 

Data Error

 LED illuminated or 

blinking? If yes, check cable length and environment. 

Video Okay

 LED is dark: CPU does not provide a video signal – Check settings of the 

graphic card. Try out, connecting a monitor to the local output, to see, whether there is a 
signal or not. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 