Draco vario Dual Link/Head KVM Extender
58
2021-07-07
In this case, choose X-ON / X-OFF software handshake for traffic control
at printer and PC.
Connection Format
DTE (Data Terminal Equipment)
Speed
Up to 115,200 Baud
Data Format
Format independent
Data Transmission
RxD (Receive Data)
TxD (Transmit Data)
Traffic Control
The following signals are transmitted
(hardware handshake):
RTS (Request To Send)
CTS (Clear To Send)
DTR (Data Terminal Ready)
DSR (Data Set Ready)
Pos: 74 /806-IHSE/T echnische D aten/Schnittstell en/Seriell e Schnittstell e R S422 @ 9\mod_1362475591209_6.doc @ 71309 @ 3 @ 1
7.1.8 Serial Interface RS422
KVM Extenders with a serial interface RS422 (D-Sub 9) support a
differential full duplex transmission
up to a Baud rate of 115,200 Baud.
The CPU unit is designed as controlling device and can, for example, be
connected directly to video or media servers.
The CON unit is designed as a controlled device and so can be connected
directly to remote controllers.
Connection Format
Sony Standard
Speed
Up to 115,200 Baud
Data Format
Format independent
Data Transmission
Rx + (Receive Data)
Rx – (Receive Data)
Tx + (Transmit Data)
Tx – (Transmit Data)
The serial interface only supports one connected device per upgrade
module.
Pos: 75 /806-IHSE/T echnische D aten/Schnittstell en/474-xx (Analoge Audio-Schnittstell e) @ 7\mod_1332491046975_6.doc @ 58270 @ 3 @ 1