
Draco major
74
2011-10-11
5.3.3
Switch
You can configure the parameters for the matrix configuration in this
menu.
You have the following possibilities to access the menu:
You can select between the following settings:
Field
Selection
Description
Y (Yes)
The user can switch the video signal
from any CPU to his monitor (observer).
Keyboard/mouse control is not possible.
Note:
Switching with the key <Space> and not
<Enter>.
The operator will not be informed if
further users connect as an observer to
the CPU that is connected to his
console.
Allow Sharing
N
(No)
Function not active (default)
Y
(Yes)
The User can connect to every single
CPU as an operator, even to such ones
that are related to another user. The
previous user is set to observer status.
Note:
To share K/M control
Force
Connect
has to be activated.
Force
Connect
N
(No)
Function not active (default)
Y
(Yes)
Extension of 'Force Connect': If the user
connects to a CPU as an operator that
is already related to another user, the
connection to the previous user will be
completely disconnected.
Note: To share K/M control
Force
Disconnect
has to be deactivated.
Force
Disconnect
N
(No)
Function not active (default)