INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION

WARNING: Before starting the installation, the masonry chimney must 

be inspected by a qualified chimney sweep.

The following requirements must be respected:

1.  The chimney must be absolutely clear of any soot residue or creosote.  

Check for cracks, loose or missing bricks that could inhibit correct 

installation of the liner.

2. The clearance to combustible must be a minimum of 1” between the 

outside of the masonry and any wood framing or loose insulation.

3. The chimney must be built in accordance with the current building 

code.

4. No other appliance can be connected to the same chimney. 

5. The clearances to combustible for these fireplace connectors are 2” 

on the side and bottom and 16” at the top.

6.  The connector parts are not necessary if the connection between the 

insulated length and the stainless steel liner is done within the masonry 

chimney.

Installation:

The chimney must be relined with a stainless steel liner model Tubinox

®

*

 

or Projet

®

 SS

*

 of the same diameter as the outlet of the fireplace. If a 

stainless steel liner is used, see note below**.
For connection at a 30º angle, a special connector (BISUMA30

*

) must be 

used to connect the liner to the insulated chimney.  

* IMPORTANT NOTE - The use of a 45º connector (BISUMA

*

) is ap-

proved for use in Canada ONLY.  Installations in the USA must use the 

30º connector (BISUMA30

*

).

**  

Alternate brand rigid stainless liner or stainless flex may be substituted but 

must be listed to UL-1777 for US application and ULC-S635 for existing 

masonry or ULC-S640M for new masonry applications in Canada. The steel 

rigid or flex liner must be rated at 2100º F (1100º C).

Follow these steps:

1. Position the fireplace in its location.  Temporarily install the ASHT+

*

 

elbow on the top of the fireplace and, using a level, mark with an oval 

the location where the flue liner will enter the masonry chimney.

2. In the middle of the oval, drill a hole in the masonry chimney at 30º.

3. Increase the size of the hole until a 30º Tubinox

*

 liner elbow can be 

easily slipped through.

4. Slide the liner down from the top of the masonry chimney until you 

reach the hole level.

5. Slip through the hole a 30º liner elbow and connect it to the liner.

6.  Add a small liner section to the liner elbow which will allow the liner to 

extend at least 12” (measured at the top of the liner) from the masonry 

chimney.   

7. Seal the opening around the liner with high temperature refractory 

cement. 

8. The next steps must be done in the following order: 

See typical installation illustrated below. 

A. Select the ASHT+

*

 length that will fit between the elbow and the liner 

so that it will slide at least 2” over the liner section (You may need to 

cut the liner for a better fit).

B. Take that section and the BISUMA30

*

 cover and slide it over the liner.  

Make sure you have enough opening to be able to install the ASHT+

*

 

elbow without difficulty.

C. Install the 30º elbow on the fireplace.

D. Slide the length section back down on the elbow and twist lock the 

two together.

E.  Pull the cover down over the length and install the insulation pad over 

the liner; be careful to cover the liner completely.

F.  Slide back the cover over the insulation and fix it in place using the 3 

metal screws supplied.

*

Available from Security Chimneys

®

 

**

Available from DuraVent

®

Figure 42

FIREPLACE

1” Clearance

* Insulated Elbow

*

 

ASHT+ or

3 Screws

Insulation Pad 

and Cover

(BISUMA)

High-Temp. 

Cement

Firestop

Tubinox

*

 or Projet SS 

*

 

Stainless Steel Liner 

**

Insulated

Length

*

Masonry Chimney, 

New or Existing

Tubinox

*

 or Projet SS

*

 

Liner Must Slide at Least 2” 

Inside Length 

**

6’ 8”

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

26

Summary of Contents for Superior Fireplaces WRT3920WS

Page 1: ...andapprovalsofthissystem and could result in an unsafe and potentially dangerous installation IHP wood burning fireplaces are designed for use as a supplemental heater They are not intended for contin...

Page 2: ...intended for use with a gas log set Do not use a fireplace insert or any other product with this fireplace unless it is specified by IHP for use with this appliance Failure to follow these instructio...

Page 3: ...length to be blown in front ofanopenflamewhenthewindow is opened Keep any combustible furniture materials or decorative pillows at least 48 1219 mm from the front fireplace opening WARNING Never leav...

Page 4: ...sthecatalyticcombustor Openingthe CAT bypass damper control increases the draft allowing the unit to achieve proper operating temperatures during a cold start up It also provides more draft to prevent...

Page 5: ...For instance a long chimney will necessitate closing the damper more To obtain the proper combustion closethedampercompletely then open it about 1 4 to 1 2 6 4mm to 13mm Two medium size pieces of woo...

Page 6: ...kesabout15 30minuteswiththeCATbypass opened to reach proper light off temperatures for the catalytic combustor Step 5 Set the primary control to the desired burn level The fireplace will automatically...

Page 7: ...ed to less than 20 Wood properly seasoned is then capable of generating the heat the stove was designed to provide Greenwooddoesnotburneasily Attemptingto burn green wood often results in a lot of smo...

Page 8: ...sweep and put the combustor back in place CATALYTIC COMBUSTOR This fireplace is designed with a catalytic com bustor which will reduce pollution emissions and creosote build up while improving therma...

Page 9: ...better seal and then retightening Catalyst Bypass linkage replacement see Figure 9B Toolsrequired 2 9 16 wrenches 2square drive bit driver Withcatalystbypassinclosedposition remove 2 baffle boards fr...

Page 10: ...ombustorProblem Thermal Cracking ThiscombustordoesNOTexperiencethermalcracking Notap plicable Appliestohoneycombcombustorsonly CombustorProblem CombustorPeeling ThiscombustordoesNOTexperiencecombustor...

Page 11: ...the ashes are cold 24 to 48 hours after the fire is out Do not leave the ashes in the house as they give off carbon monoxide and other toxic gases WARNING DisposalofAshes Ashesshould be placed in a st...

Page 12: ...e Replacement Parts Page 28 DO NOT OPERATE THE UNIT WITH CRACKED OR BROKEN GLASS Glass Cleaning TheWRT3920WSfireplaceisdesignedtokeeptheglasscleanundernormal operating conditions If the WRT3920WS fire...

Page 13: ...replace is determined by considering the location of windows doors and the traffic flow in the room where the fireplace is located allowing space in front of the unit for the hearth exten sion and the...

Page 14: ...must cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with at least a 1 2 inch of non combustible material tile marble stone etc See Figure 15 CO...

Page 15: ...phs are not to scale consult installation instructions Product designs materials dimensions specifications colorsandpricesaresubjecttochangeordiscontinu ance without notice Allframingdimensionscalcula...

Page 16: ...Side Figure 17 Figure 18 Insulated Chase Construction 7 Ft Min Attic Radiation Shield Roof Support Storm Collar Flashing Drywall or Any Rigid Material 2 x 4 1 2 Plywood 6 8 Min Firestop Floor Ceiling...

Page 17: ...mbustible Facing Drywall 2 x 3 Min Rock Board or Other Spacer Figure 22 A wall on off switch must be installed to control theblower Anoptionalheatswitchandvariable speed control are available see Page...

Page 18: ...ust be non combustible below this area u NOTES Seal the top and both sides of the roof flashing with waterproof caulk ing The gap between the vent pipe and a vertical firestop shall be sealed with non...

Page 19: ...the base of the fireplace C The fresh air must come from outside the house The air intake must not draw air from the attic basement or garage D The air intake should be installed where it is not likel...

Page 20: ...2 feet 3 7 m In altitude add 18 450 mm to the chimney for every 2 000 feet 600 m above sea level 6 All chimney installations must include at least one support Re ducing the amount of chimney weight on...

Page 21: ...the joint between the roof and the flashing with roofing pitch see Figures 34 and 35 For sloping roofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to...

Page 22: ...b bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below install...

Page 23: ...6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 2432 mm...

Page 24: ...Insulated Wall Angel Wall Radiation Shield Insulated Available from Security Chimneys Available from DuraVent Security Chimneys RSM and RSMI30 RSMI45 Canada Only DuraVent 6DTC WTI and 6DTC S30 6DTC S...

Page 25: ...AND MULTIPLE TERMINATIONS For the purpose of this manual a chimney chase is considered a part of the chimney system rather than part of a building The termination must be placed a minimum of 18 460 mm...

Page 26: ...rily install the ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in...

Page 27: ...er EPA certification If installed this appliance no longer qualifies for EPA certification Check with local authorities having jurisdiction for requirements in your area Central Forced Air Kit Accesso...

Page 28: ...ription Part Cat No Andiron 2 pieces PR SR2875 Bottom refractory PR SR2825 Back refractory PR SR2826 Left side refractory PR SR2828 Right side refractory PR SR2827 Front refractory 2 pieces PR SR2829...

Page 29: ...nd PE Wall Band BM Supports Offset Support SO Roof Support ST Roof Brace BS2 Firestops Firestop 6BF Radiation Shield 6RS Insulated Attic Radiation Shield 6RSA2 Insulated Wall Radiation Shield 6RSM Ins...

Page 30: ...Relining A Masonry Chimney 6 Diameter Listed to ULC S635M UL 1777 and ULC S640M at 2100 F Description Cat Part No 6 Length 6 Dia 6LL6 6LL6 12 Length 6 Dia 6LL12 6LL12 24 Length 6 Dia 6LL24 6LL24 36 Le...

Page 31: ...E MANUEL D INSTALLATION LES COMPOSANTES UTILIS ES AVEC LE FOYER DOIVENT TRE HO MOLOGU ES VOIR LA LISTE DANS LE MANUEL D INSTALLATION REMPLACER LA VITRE AVEC UN VERRE C RAMIQUE DE 5mm D PAISSEUR POUR U...

Page 32: ...ct d damages repairs or inefficiency resulting from faulty installation or application of the Product IHP is not responsible for inadequate system draft caused by air conditioning and heating systems...

Page 33: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Page 34: ...See Page 28 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at pr...

Reviews: