16
P506009-24
Printed in U.S.A. © 2014 Innovative Hearth Products
P/N 506009-24 REV. A 01/2016
IHP reserves the right to make changes at any time, without notice, in design, materials,
specifications, prices and also to discontinue colors, styles and products. Consult your local
distributor for fireplace code information.
Figure 21
Figure 20
Figure 22
NOTE: If the igniter is damaged, a re-
placement kit is available, order Catalog
Number 87L54.
Step 6
.
(Refer to
Figure 19
on
Page 15
)
A.
Remove the orifice from the manifold with
a 1/2" deep throat socket. See the following
table for orifice sizes for natural and propane
models
. Figure 22
illustrates the orifice.
Use pipe joint compound or Teflon tape on
all pipe fittings before installing (ensure
propane resistant compounds are used in
propane applications, do not use pipe joint
compounds on flare fittings).
B.
Retrieve the burner and slide the venturi tube
over the orifice. Secure the burner in place
with the clip shown in
Figure 19
.
Step 7.
Reassemble the remaining components
by reversing the procedures outlined in the
preceding steps.
ELECTRONIC PILOT
Pilot
Hood
Sensor
Igniter
PROPANE
NATURAL
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Pilot Stage
Terminal
Pressure-Tap
(Inlet)
Pilot Gas
Outlet
Supply
Gas
Inlet
Pressure-Tap
(Manifold)
Burner Stage
Terminal
Ground
(TP)
PILOT
OUT
VENT
LO
TH
TP
TH
TP
HI
IN
IN
Gas Outlet
To Burner
Regulator
Mounting Screw
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
Burner Orifice Sizes
Elevation 0-4500 feet ( 0-1372 meters)
Model
Nat.Gas
drill size (inches)
Propane
drill size (inches)
VRE4336
#28 (.1405")
#47 (.0785")
VRE4342
#28 (.1405")
#47 (.0785")