Figure 21

Figure 20

Figure 22

NOTE: If the igniter is damaged, a re-

placement kit is available, order Catalog 

Number 87L54.

Step 6

(Refer to 

Figure 19

 on 

Page 15

)

A.

 Remove  the orifice from the manifold with 

a 1/2" deep throat socket. See the following 

table for orifice sizes for natural and propane 

models

. Figure 22

 illustrates the orifice. 

Use pipe joint compound or Teflon tape on 

all pipe fittings before installing (ensure 

propane resistant compounds are used in 

propane applications, do not use pipe joint 

compounds on flare fittings). 

B.

  Retrieve the burner and slide the venturi tube  

over the orifice. Secure the burner in place 

with the clip shown in 

Figure 19

.

Step 7.

 Reassemble the remaining components 

by reversing the procedures outlined in the 

preceding steps. 

ELECTRONIC PILOT

Pilot

Hood

Sensor

Igniter

PROPANE

NATURAL

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Pilot Stage

Terminal

Pressure-Tap

(Inlet)

Pilot Gas

Outlet

Supply

Gas

Inlet

Pressure-Tap

(Manifold)

Burner Stage

Terminal

Ground

(TP)

PILOT

OUT

VENT

LO

TH

TP

TH

TP

HI

IN

IN

Gas Outlet

To Burner

Regulator

Mounting Screw

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Burner Orifice Sizes 

Elevation 0-4500 feet ( 0-1372 meters)

Model

Nat.Gas

drill size (inches)

Propane

drill size (inches)

VRE4336

#28 (.1405")

#47 (.0785")

VRE4342

#28 (.1405")

#47 (.0785")

Summary of Contents for Superior Fireplaces Elite VRE4336ZEN

Page 1: ...lame 3 If odor continues keep away from the appli ance and immediately call your gas supplier or your fire department DANGER MONOXYDE DE CARBONE Cet appareil peut produire du monoxyde de carbone un gaz inodore Son utilisation dans un espace clos peut vous tuer Ne jamais utiliser cet appareil dans un es pace clos tel qu une caravane tente voiture ou à la maison Avertissement Pour utilisation à l ex...

Page 2: ...7 feet 8 inches A minimum of two 2 walls can be screened but must be open to outside ventilation Minimum screen area 64 square feet Minimum screen top height 6 feet 8 inches Refer to Outdoor Space definition below and Clearance Specifications on Page 6 These appliances are designed to operate on natural gas or propane An electronic inter mittent pilot ignition system provides safe efficient operat...

Page 3: ... REQUIREMENTS These appliances may be installed in the following USA locations with the following requirements Installation of these appliances are approved for installation in the US state of Massachu setts if the following additional requirements are met Installation and repair must be done by a plumber or gas fitter licensed in the Com monwealth of Massachusetts The flexible gas line connectors...

Page 4: ...tional drip pan see Waterproofing The Fireplace and Figure 3 on Page 5 4 Plumb gas line Gas connections should only be performed by an experienced licensed certified tradesman 5 Complete the installation finish wall mate rial surround and hearth extension to your individual taste 6 Assemble and attach optional accessories Study the three dimensional illustration Fig ure 1 to get a general idea of ...

Page 5: ...and back 1 2 13mm combustible floor 0 0mm adja centwall6 152mm ceiling 72 1829mm Refer to Figure 4 on this page and Figure 18 on Page 13 for more detail NOTE Clearance behind the nailing flange for both fireplace models is 1 2 13mm NOTE Adjacent wall considerations are for an adjacent wall to only a single side Walls shouldnotbeplacedattheminimumdistance on both sides of the fireplace Allow at lea...

Page 6: ...hall not open directly above a sidewalk or paved driveway which is located between two single family dwellings and services both dwellings Only permitted if veranda porch deck or balcony is fully open on a minimum of 2 sides beneath the floor or if the screened porch guidelines are followed Note 1 Local codes or regulations may re uire dif ferent clearances Note 2 Fireplaces in an alcove space spa...

Page 7: ... the box to ensure proper length Secure the umbilicalcordperappropriatelocalandnational electrical codes FIREPLACE INSTALLATION Step 1 Frametheseappliancesasillustratedin Figures 7 through 9 All framing details must allow for a minimum clearance to combustible framing members as shown in Figure 4 on Page 5 Also refer to Fireplace Specifications on Page 8 Headers may be in direct contact with the a...

Page 8: ...es millimeters Model No A B C 37 940 41 3 4 1061 23 1 2 597 43 1092 47 3 4 1213 29 1 2 749 1 3 4 28 1 2 724 41 3 8 1051 34 1 4 870 5 127 20 508 12 305 4 3 8 111 Left Side Gas Inlet 8 1 4 210 2 51 Model Ship Weight lbs Shipping Volume 230 lbs 38 Cu Ft Weight And Volume 200 lbs 35 Cu Ft Polaris36 Polaris42 Polaris36 Polaris42 Model Ship Wt Shipping Volume Polaris36 200 lbs 35 Cu Ft Polaris42 230 lbs...

Page 9: ...cluding Finishing Materials If Any Rough Framing Face Unfinished Shown C G A Parallel Installation Rough Framing Face Unfinished Shown Back Wall Of Chase Enclosure Including Finished Materials If Any Opening VRE4336 VRE4342 A 42 3 4 1086 48 3 4 1238 B 46 1 2 1181 46 1 2 1181 C 23 5 8 600 29 5 8 753 D 11 1 4 286 14 1 4 362 E 63 1 2 1613 69 1 2 1765 F 31 3 4 807 34 3 4 883 G 20 1 2 521 20 1 2 521 H ...

Page 10: ...nec tion when servicing controls Wiring errors cancauseimproperanddangerousoperation Verify proper operation after servicing Refer to Figure 10 for the wiring schematic for these fireplaces This fireplace is completely wired internally On the right hand side of the fireplace at the rear are four 4 wires required to connect the Battery and switch for operation Two brown wires are for the connection...

Page 11: ...opriate toolsandsealingcompounds ensurepropane resistant compounds are used in propane applications Turn on gas supply and test for gas leaks us ing a gas leak test solution also referred to as bubble leak solution NOTE Using a soapy water solution 50 dish soap 50 water is an effective leak test solution but it is not recommended because the soap residue that is left on the pies fittings can resul...

Page 12: ...hown in Figure 15 The remaining logs can be placed across the rear and base log approximately as shown in Figure 16 The exact position of these logs is not critical Due to the nature of an outdoor environment the flame will never be strictly controlled You may need to reposition the logs to get the effect you find most desirable A more detailed description is provided in the Care and Operation man...

Page 13: ...ilotflamewillengulfthe sensorandopenthemainvalve Withinseconds the main burner will light Ensure the igniter lights the pilot The pilot flame should engulf the sensor as shown in Figure 17 ELECTRONIC Pilot Hood Sensor Igniter Figure 17 Figure 18 Clearances To Combustibles 6 Minimum For Combustible Materials 12 Max 3 3 4 Max See Note 22 Min 29 Min Wall Switch 5 Min Note The Area Above The Face To T...

Page 14: ...an Cat No Model Description H4651 DPSS36 Drain Pan 36 H4652 DPSS42 Drain Pan The drain pan is used with the appliance Drain Pan 42 INSTALLATION ACCESSORIES AND COMPONENTS Drain Pan Cat No Model Description H4651 DPSS36 Drain Pan 36 H4652 DPSS42 Drain Pan 42 ...

Page 15: ...selonlesinstructionsdufabricantetselontouteslesexigencesettousles codes pertinents de l autorité compétente Assurez vous de bien suivre les instructions dans cette notice pour réduire au minimum le risque d incendie d explosionoulaproductiondemonoxydedecarbonepouvant causer des dommages matériels des blessures ou la mort Le tecnicien agrééestresponsabledel installationdecettetrousse L installation...

Page 16: ...fittings before installing ensure propane resistant compounds are used in propane applications do not use pipe joint compounds on flare fittings B Retrievetheburnerandslidetheventuritube over the orifice Secure the burner in place with the clip shown in Figure 19 Step7 Reassembletheremainingcomponents by reversing the procedures outlined in the preceding steps ELECTRONIC PILOT Pilot Hood Sensor Ig...

Reviews: