IHP SEREFINA CI1500 GCK LP Installation Instructions Manual Download Page 6

Printed in U.S.A. © 2013 IhP LLC

P/N  506033-81  Rev. A  11/2013

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

IHP reserves the right to make changes at any time, without notice, in design, materials, 

specifications, and prices, and also to discontinue colors, styles, and products. Consult your 

local distributor for fireplace code information.

6

f i r e - p a r t s . c o m

Summary of Contents for SEREFINA CI1500 GCK LP

Page 1: ...cordancewiththerequirements of the CAN CGA B149 1 Installation code AVERTISSEMENT Cet équipement de conversion sera installé par une agencequalifiéedeserviceconformémentauxinstruc tionsdufabricantettoutesexigencesetcodesapplica blesdel autorisésavoirlajuridiction Sil information danscetteinstructionn estpassuivieexactement un feu explosionouproductiondeprotoxydedecarbone peutrésulterledommagescaus...

Page 2: ...eflon tape on all pipe fittings before installing ensure propane resistant compounds are used do not use pipe joint compounds on flare fittings The burner orifice provided in this kit IS only for use at elevationsof0to4 500feet 0 1372M Athigherelevations the BTU input must be de rated by 4 for every 1 000 feet 305 M to maintain the proper ratio of gas to air Iftheinstallermustconverttheunittoadjus...

Page 3: ... and install the new pressure regulator using the new screws supplied with this kit Tighten screws to 25 in lbs of torque Step 7 Install the enclosed identification label to the inside of the control access door where it can be easily seen see Figure 8 Pressure Regulator Remove These Components Figure 8 Figure 9 Step 8 Refer to Figure 9 Remove the pilot hood assembly to access the hexed pilot orif...

Page 4: ... and connections with the gas leak test solution to check for leaks If bubbles are formed or gas odor is detected turn the gas control knob off pilot on to the OFF position Either tighten or refasten the leaking connection then retest as described above C When the gas lines are tested and leak free be sure to rinse off the leak testing solution Step 14 Relight the main burner and verify proper bur...

Page 5: ...erve the flame continuously If it appears weak or sooty adjust the air shutter to a more open position until the desired flame appearance is achieved Adjusting Burner Air Shutter WARNING Air shutter adjustment should only be performed by a qualified professional service technician Ensure front glass panel are in place and sealed during adjustment CAUTION Soot will be produced if the air shutter is...

Page 6: ...ike Suite 108 Nashville TN 37210 IHP reserves the right to make changes at any time without notice in design materials specifications and prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 6 fire parts com ...