background image

KIT CONTENTS

 1 ea.  Nova SIT LP Regulator Kit (A)

 1 ea.  LP main burner orifice (B)

 1 ea.  LP pilot orifice (C)

 1 ea.  Sticker, LP Conversion (D)

 1 ea.  Instruction Sheet

TOOLS NEEDED

5/32” Allen Wrench Or T-Handle Wrench

#2 Phillips Screwdriver 

1/2” Open End Wrench

Torx T20, Or Flat Screwdriver

SEREFINA™ GAS CONvERSION KITS, NG TO LP

INSTALLATION INSTRUCTIONS FOR CONvERTING FROM NATURAL GAS (NG) TO 
PROPANE GAS (LP).  FOR USE wITh SEREFINA™ DIRECT vENT GAS STOvES

506033-81 
Rev. A, 11/2013

HEARTH PRODUCTS

KITS AND ACCESSORIES

       

wARNING

This conversion kit shall be installed by a qualified 

service agency in accordance with the manufacturer's 

instructions and all applicable codes and requirements 

of the authority having jurisdiction.  If the information 

in these instructions is not followed exactly, a fire, 

explosion or production of carbon monoxide may result 

causing property damage, personal injury or loss of 

life.  The qualified service agency performing this 

installation is responsible for the proper installation 

of this kit and assumes responsibility for this conver-

sion. The installation is not proper and complete until 

the operation of the converted appliance is checked as 

specified in the manufacturers instructions supplied 

with the kit. 

 IMPORTANT LE CANADA SEULEMENT

La conversion devra être effectuée conformément 

aux recommandations des autorités provinciales 

ayant juridiction et conformément aux exigences 

du code d'installation CAN/CGA B149.1.

         IMPORTANT CANADA

The conversion shall be carried out in accordance with 

the requirements of the provincial authorities having 

jurisdiction and in accordance with the requirements 

of the CAN/CGA B149.1 Installation code.

            

AvERTISSEMENT

Cet équipement de conversion sera installé par une 

agence qualifiée de service conformément aux instruc-

tions du fabricant et toutes exigences et codes applica-

bles de l'autorisés avoir la juridiction.  Si l'information 

dans cette instruction n'est pas suivie exactement, un 

feu, explosion ou production de protoxyde de carbone 

peut résulter le dommages causer de propriété, perte 

ou blessure personnelle de vie.  L'agence qualifiée de 

service est esponsable de l'installation propre de cet 

équipment.  L'installation n'est pas propre et compléte 

jusqu'à l'opération de l'appareil converti est chéque 

suivant les critères établis dans les instructions de 

propriétaire provisionnées avec l'équipement.

         IMPORTANT

The burner orifices provided in this kit are only for 

use at elevations of 0 to 4,500 feet (0-1372 M) in 

Canada.  At higher elevations the BTU input must 

be de-rated by 4% for every 1,000 feet (305 M) to 

maintain the proper ratio of gas to air.  If the installer 

must convert the unit to adjust for varying altitudes, 

a deration information sticker must be filled out by 

the installer and adhered to the appliance at the time 

of the conversion. Contact your local gas supplier 

for deration requirements for your area. 

A

Figure 1 - Kit Contents

B

THIS APPLIANCE HAS BEEN CONVERTED TO: 

PROPANE GAS 

INPUT BTU/HR – 27,000 

MANIFOLD PRESSURE – 10” 

ORIFICE SIZE: .061” 

                                                                                                LB-102159A 

C

D

THIS APPLIANCE HAS BEEN CONVERTED TO: 

PROPANE GAS 

INPUT BTU/HR – 34,500 

MANIFOLD PRESSURE – 10” 

ORIFICE SIZE: .0675” 

                                                                                                LB-102159B 

CI1500DvF

CI2500DvF

Natural Gas to Propane Gas Converion Kits

Cat. No.

Model

Description

h3705

CI1500 GCK LP

CI1500 Gas Conversion Kit, NG to LP

h3706

CI2500 GCK LP

CI2500 Gas Conversion Kit, NG to LP

1

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

f i r e - p a r t s . c o m

Summary of Contents for SEREFINA CI1500 GCK LP

Page 1: ...cordancewiththerequirements of the CAN CGA B149 1 Installation code AVERTISSEMENT Cet équipement de conversion sera installé par une agencequalifiéedeserviceconformémentauxinstruc tionsdufabricantettoutesexigencesetcodesapplica blesdel autorisésavoirlajuridiction Sil information danscetteinstructionn estpassuivieexactement un feu explosionouproductiondeprotoxydedecarbone peutrésulterledommagescaus...

Page 2: ...eflon tape on all pipe fittings before installing ensure propane resistant compounds are used do not use pipe joint compounds on flare fittings The burner orifice provided in this kit IS only for use at elevationsof0to4 500feet 0 1372M Athigherelevations the BTU input must be de rated by 4 for every 1 000 feet 305 M to maintain the proper ratio of gas to air Iftheinstallermustconverttheunittoadjus...

Page 3: ... and install the new pressure regulator using the new screws supplied with this kit Tighten screws to 25 in lbs of torque Step 7 Install the enclosed identification label to the inside of the control access door where it can be easily seen see Figure 8 Pressure Regulator Remove These Components Figure 8 Figure 9 Step 8 Refer to Figure 9 Remove the pilot hood assembly to access the hexed pilot orif...

Page 4: ... and connections with the gas leak test solution to check for leaks If bubbles are formed or gas odor is detected turn the gas control knob off pilot on to the OFF position Either tighten or refasten the leaking connection then retest as described above C When the gas lines are tested and leak free be sure to rinse off the leak testing solution Step 14 Relight the main burner and verify proper bur...

Page 5: ...erve the flame continuously If it appears weak or sooty adjust the air shutter to a more open position until the desired flame appearance is achieved Adjusting Burner Air Shutter WARNING Air shutter adjustment should only be performed by a qualified professional service technician Ensure front glass panel are in place and sealed during adjustment CAUTION Soot will be produced if the air shutter is...

Page 6: ...ike Suite 108 Nashville TN 37210 IHP reserves the right to make changes at any time without notice in design materials specifications and prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 6 fire parts com ...