WALL MOUNT

The transmitter can be placed on a wall using the mount provided.

Wood - Drill 1/8’’ pilot holes and install with screws provided.

• 

Plaster/Wallboard - Drill 1/4’’ holes, use a hammer to tap in the two plastic 

• 

anchors. Then install with the screws provided.

Fig. 26

BATTERY LIFE

Life expectancy of the alkaline batteries in the transmitter and receiver should be at least 12 months.  Check and replace 

all batteries:

Annually.

• 

When operating range becomes reduced.

• 

When transmissions are not received by the remote receiver.

• 

If the remote receiver batteries measure less than 5.3 volts (all (4) batteries in combination).

• 

If the hand held transmitter batteries measure less than 5.3 volts all (4) batteries in combination).

• 

TROUBLE SHOOTING

If you encounter problems with your fireplace system, the problem may be with either the fireplace itself or with the 

remote.  Review the fireplace manufacturer’s operation manual to make sure all connections are properly made.  Then 

check the operation of the remote in the following manner:

Make sure all batteries are correctly installed in the transmitter and receiver. Also check that the batteries are fully 

• 

charged.

Check batteries in transmitter to ensure contacts are touching (+) and (-) ends of battery. Bend metal contacts in for 

• 

tighter fit.

Be sure receiver and transmitter is within 20 to 25-foot operating range.

• 

Keep receiver from temperatures exceeding 130º F. Battery life will be shortened if exposed to high temperatures.

• 

If receiver is installed in a tightly enclosed metal surrounding, the operating distance will be shortened.

• 

Make sure the hand-held transmitter and remote receiver are communicating properly (see LEARNING 

• 

       TRANSMITTER TO RECEIVER section).

FCC REQUIREMENTS

NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODI-

FICATIONS TO THE EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT

P/N 900259-00 Rev. A

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you 

purchased the product.  If you cannot locate the dealer/distributor, then you must notify IHP in writing.  IHP must be 

notified of the claimed defect in writing within 90 days of the date of failure.  Notices should be directed to the IHP 

Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our 

website at www.IHP.us.com

Summary of Contents for RC-S-TOUCH

Page 1: ...ntrol system was developed to provide a safe reliable and user friendly remote control system for gas heating appliances The system can be operated thermostatically manually or with the built in factory program inside the transmitter The built in program has two segments a weekdays and a weekend segment The factory presets are time periods for each day SEE PROGRAM SEQUENCE BELOW Custom programming...

Page 2: ...es the appliance On Thermo Off PROGRAM 2 Turns ON and OFF the program function SET 3 Used in different functions to confirm settings UP 4 and DOWN Used to change the time set temp and programming functions MODE SET PROG 1 1 2 2 3 4 3 Fig 2 BATTERY ICON 1 Battery power is low Replace Batteries in 2 4 weeks ROOM 2 Indicates CURRENT room temperature SET 3 Indicates desired SET room temperature for TH...

Page 3: ...ons and wiring schematics for proper placement of all wires All electronic modules are to be wired to manufacturer s specifications The following wiring diagrams are for illustration purpose only Follow instructions from manufacturer of gas valve and or electronic module for correct wiring procedures Improper installation of electric components can cause damage to electronic module gas valve and r...

Page 4: ...9 FIG 11 FIG 10 REV 3 18 14 Page 4 WIRING INSTRUCTIONS A qualified electrician should install the remote control system TERMINAL BLOCK ON MILLIVOLT GAS VALVES TH TP TP TH THERMOPILE PILOT LIGHT REMOTE RECEIVER Connect one wire from the remote receiver to the TH terminal on the gas valve Connect the other wire from the remote receiver to the TH TP terminal on the gas valve WIRING MILLIVOLT VALVES M...

Page 5: ...eiver to accept the transmitter security code upon initial use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the receiver to accept the transmitter security code be sure the slide button on the receiver is in the REMOTE position the receiver will not LEARN if the slide switch is in the ON or OFF position The LEARN button in loca...

Page 6: ... Saturday and Sunday Weekday Segment 3 Monday through Friday Flame ON 4 Flame icon shows your appliance to turn ON Flame OFF 5 Flame icon shows your appliance to turn OFF 1 4 5 2 3 Fig 16 To edit the program settings press either the PROG button or touch the Program section of the touch screen and hold for 5 seconds the program section of the LCD screen will begin to flash P1 ON and S S Weekend Se...

Page 7: ...tes to the receiver indicating that the transmitter is within the normal operating range of 20 feet Should the receiver NOT receive a transmitter signal every 15 minutes the receiver will begin a 2 hour 120 minute countdown timing function If during this 2 hour period the receiver does not receive a signal from the transmitter the receiver will shut down the appliance being controlled by the recei...

Page 8: ...lso check that the batteries are fully charged Check batteries in transmitter to ensure contacts are touching and ends of battery Bend metal contacts in for tighter fit Be sure receiver and transmitter is within 20 to 25 foot operating range Keep receiver from temperatures exceeding 130º F Battery life will be shortened if exposed to high temperatures If receiver is installed in a tightly enclosed...

Reviews: