AUTO SHUT DOWN
This remote control has an auto shut down feature incorporated into its system. When the transmitter mode is in the ON position, the
appliance will only run for 9 hours. After that it will shut down. To reactivate the appliance, press the
MODE
button.
CP (CHILDPROOF) FEATURE
This remote control includes a childproof feature that allows the user to “lock-out” operations from the transmitter.
•
To activate and de-activate the childproof feature, press and hold the
SETTING
button
behind the battery cover, for 5 seconds
(SEE The letters “CP” will briefly appear on the LCD screen when childproof mode is activated).
•
“CP” will appear on the LCD screen if any button is pressed while childproof mode is engaged.
•
When this mode is engaged, all auto settings go on without interruption (like thermostat). Only manual functions are prevented.
TRANSMITTER WALL BRACKET
The transmitter can be hung on a wall using the clip provided.
•
Wood - Drill 1/8’’ pilot holes and install with screws provided.
•
Plaster/Wallboard - Drill 1/4’’ holes, tap anchors in with hammer, then
install with the screws provided.
Slide Transmitter
down into holder
BATTERY LIFE
Life expectancy of the alkaline batteries in the transmitter should be at least 12 months. Check and replace all batteries:
•
Annually.
•
When operating range becomes reduced.
•
When transmissions are not received by the remote receiver..
•
If the hand held transmitter batteries measure less than 2.4 volts (Both batteries in combination).
REV. 1-8-15 Page 5
IHP: RC-S-MODMV
P/N 900258-00 Rev. B
COMMUNICATION - SAFETY - TRANSMITTER - (C/S - T/X)
This remote control has a COMMUNICATION –SAFETY function built into its software to ensure the transmitter and receiver are com-
municating normally.
In all operating modes, the transmitter sends an RF signal every fifteen minutes to the receiver indicating that the transmitter is within
the normal operating range of 20-feet. Should the receiver NOT receive this signal, the receiver will begin a 2-hour countdown. If the
receiver does not receive a signal from the transmitter in 2 hours, the receiver will shut off the appliance. The receiver will then emit a
series of rapid “beeps” for a period of 10 seconds. Then after 10 seconds of rapid beeping, the receiver will continue to emit a single
“beep” every 2 seconds until a transmitter
MODE
Button is pressed to reset the receiver.
INSTALLING FAN/BLOWER
OFF REMO
TE ON
LEARN
GROUND
VALV
E
FLAM
E
CONTROL
Line cord
from fan
Plug 2 or 3 prong plug fan cord directly into the 3
prong polarized plug on back of the receiver. This
receptacle receiver is rated at 110/120VAC, 3AMP.