5
. Secure the air gate arm support bracket (item
#3 in
Figure 1)
as shown in
Figure 9
.
4
. Secure the air gate to the fi rebox as shown
in
Figure 8
.
7
. Attach fl exible duct to the outside air collar
using two (2) short screws (provided), then
wrap with duct tape as shown in
Figure 11
.
Printed in U.S.A. © 2006 Innovative Hearth Products
P/N 750206M REV. B 05/2017
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Hold the air gate arm and align the air gate assem-
bly to fi t fl ush in the opening.
Figure 6
Figure 12
8
.
Duct Hole Framing:
Cut or frame a hole through
the outside of the enclosure for the installation
of the duct inlet hood. A 5" (127 mm) diameter
hole is required. Feed the loose end of the fl exible
duct through the hole cut for the inlet hood and
attach to the collar on the inlet hood using two
(2) short screws (provided), then wrap with duct
tape. Insert the hood into the opening. Secure in
place with nails driven through the holes in hood
fl ange. Seal with noncombustible waterproof
silicon type caulking. If additional duct is needed,
use Class 0 metallic air duct (refer to
Figure 12
)
.
NOTE:
The Class 0 metallic air duct can be routed
out the back wall or side wall, up through the ceiling
or fl oor joists to an outside wall. Check local build-
ing codes for any restrictions. We recommend that
the inlet be at least four (4) feet above grade level.
4" (102 mm)
Class 0 air duct
Hood
Air Inlet
Secure the hood
to a vertical post
with the inlet posi-
tioned downward.
• IN COLD CLIMATES
THE AIR DUCT SHOULD
BE INSULATED.
CAUTION
Do not install the air inlet in the attic,
garage, near combustible gases (i.e.
paint, gasoline, etc.) or where there
is a fuel burning appliance or where
the opening could be blocked by snow,
bushes or other obstacles.
6
. Secure the outside air collar (item #4 in
Figure
1)
as shown in
Figure 10
.
Innovative Hearth Products
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
IHP reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and the discontinuance of colors, styles and products. Consult your local distributor
for fi replace code information.
Air Gate Arm
Front right
side of fi rebox
opening
Locate this opening
Feed the bent end of the air gate arm
into this notched opening.
Figure 7
OPEN POSITION
CLOSED POSITION
Air
Gate
Secure the Air Gate to the fi replace with four
(4) long screws (provided) through the outside
holes (indicated by arrows).
Right Side
of Firebox
Figure 8
Ensure this
notch is
positioned
on the
bottom half
of air gate.
Locate this slot on right
side panel of fi rebox.
Slot
Insert the arm support bracket as shown.
Adjust arm as necessary to rest on the bracket
Slot
Bracket
Secure the
bracket with a
screw provided.
Long
Screw
Figure 9
Bracket
Outside
Air
Collar
Secure the outside air collar over the air gate
using the four (4) long screws (provided)
through the inside holes (indicated by arrows).
Figure 10
Collar
Secure the duct to
the collar using
duct tape as
shown.
Figure 11
f i r e - p a r t s . c o m