IHP.US.com
126905-01_B
7
OPERATING INSTRUCTIONS
FOR GA9050A-1 SERIES
1. STOP! Read the safety information, in the owner’s manual in-
cluded with your hearth kit.
2. Make sure equipment shutoff valve is fully open.
3. Press in and turn control knob clockwise
to the OFF posi-
tion.
4. Wait five (5) minutes to clear out any gas. Then smell for gas
around log set and near floor. If you smell gas, STOP! See
Safety
information and
Air For Combustion and Ventilation
, in your hearth
kit owner’s manual. If you don’t smell gas, go to the next step.
5. Turn control knob counterclockwise
to the PILOT position
and press in. Keep control knob pressed in for five (5) seconds.
Note:
You may be running this log set for the first time after hook-
ing up to gas supply. If so, control knob may need to be pressed
in for 30 seconds or more. This will allow air to bleed from gas
system
.
6. With control knob pressed in, push down and release ignitor
button. This will light pilot. The pilot is attached to the rear of the
front burner. If needed, keep pressing ignitor button until pilot
lights.
Note:
If pilot does not stay lit, contact a qualified service person
or gas supplier for repairs. Until repairs are made, light pilot with
match
.
7. Keep control knob pressed in for 30 seconds after lighting pilot.
After 30 seconds, release control knob.
Note:
If pilot goes out, repeat steps 3 through 7.
If control knob does not pop up when released, contact a qualified
service person or gas supplier for repairs.
8. Turn control knob counterclockwise
to the ON position.
Burner should light. If burner does not light, call a qualified service
person.
9. To leave pilot lit and shut off burners only, turn control knob
clockwise
to the PILOT position.
Note:
Follow the Troubleshooting section in the owner’s manual
included with your hearth kit
.
OPERATING APPLIANCE
Figure 15 - Ignitor and Control Knob
Ignitor
Pilot
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
PULL PUSH
TO LIGHT
ON
ON
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
PULL PUSH
TO LIGHT
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF PULL PUSH TO LIGHT
ON
OFF
On
Off
OFF
OFF
Control Knob
Figure 16 - Thermocouple and Pilot
Pilot
Thermocouple
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
to the PILOT position.
2. Press in and turn control clockwise
to the OFF position.
3. Close equipment shutoff valve (see Figure 4, page 4).
f i r e - p a r t s . c o m