OPERATING INSTRUCTIONS 

FOR GA9050A-1 SERIES

1.  STOP! Read the safety information, in the owner’s manual in-

cluded with your hearth kit.

2.  Make sure equipment shutoff valve is fully open.
3.  Press in and turn control knob clockwise 

 to the OFF posi-

tion.

4.  Wait five (5) minutes to clear out any gas. Then smell for gas 

around log set and near floor. If you smell gas, STOP! See 

Safety

 

information and 

Air For Combustion and Ventilation

, in your hearth 

kit owner’s manual. If you don’t smell gas, go to the next step.

5.  Turn control knob counterclockwise 

 to the PILOT position 

and press in. Keep control knob pressed in for five (5) seconds.

 

Note: 

You may be running this log set for the first time after hook-

ing up to gas supply. If so, control knob may need to be pressed 

in for 30 seconds or more. This will allow air to bleed from gas 

system

.

6.  With control knob pressed in, push down and release ignitor 

button. This will light pilot. The pilot is attached to the rear of the 

front burner. If needed, keep pressing ignitor button until pilot 

lights.

 

Note:

 If pilot does not stay lit, contact a qualified service person 

or gas supplier for repairs. Until repairs are made, light pilot with 

match

.

7.  Keep control knob pressed in for 30 seconds after lighting pilot. 

After 30 seconds, release control knob.

 

Note:

 If pilot goes out, repeat steps 3 through 7.

  If control knob does not pop up when released, contact a qualified 

service person or gas supplier for repairs.

8.  Turn control knob counterclockwise 

 to the ON position. 

Burner should light. If burner does not light, call a qualified service 

person.

9.  To leave pilot lit and shut off burners only, turn control knob 

clockwise 

 to the PILOT position.

 

Note:

 Follow the Troubleshooting section in the owner’s manual 

included with your hearth kit

.

OPERATING APPLIANCE

Figure 15 - Ignitor and Control Knob

Ignitor

Pilot

FROM "PILOT" POSITION

SLIGHT PUSH TO 

TURN OFF 

PULL PUSH 

TO LIGHT

ON

ON

FROM "PILOT" POSITION

SLIGHT PUSH TO 

TURN OFF 

PULL PUSH 

TO LIGHT

FROM "PILOT" POSITION

SLIGHT PUSH TO 

TURN OFF  PULL PUSH  TO LIGHT

ON

OFF

On

Off

OFF

OFF

Control Knob

Figure 16 - Thermocouple and Pilot

Pilot

Thermocouple

TO TURN OFF GAS 

TO APPLIANCE

1.  Turn control knob clockwise 

 to the PILOT position.

2.  Press in and turn control clockwise 

 to the OFF position.

3.  Close equipment shutoff valve (see Figure 4, page 4).

f i r e - p a r t s . c o m

Summary of Contents for GA9050A-1

Page 1: ...01 Pilot Valve Dial Extension 3 901080 01 Propane Conversion Decal 901691 01 P126905 01 INSTALLATION INSTRUCTIONS MANUALON OFFSAFETYVALVE PILOTKIT MODEL GA9050A 1 F0235 For All Single Dual and Triple Burner Natural and Propane LP Gas Logs WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Installation and service must ...

Page 2: ...iple Burner 65 000 55 000 8 dia BFLT24 24 Triple Burner 70 000 60 000 8 dia Add 6 if safety valve pilot is used At depth indicated FUEL INLET PRESSURE SPECIFICATIONS W C Gas Min Max NG 5 5 10 5 LP 11 13 BURNER ORIFICE NATURAL PROPANE LP LOG SIZE IN NUM CLR IN NUM CLR 18SR DR 0 120 31 Blue 0 073 49 Red 24SR DR BFLT18 0 129 30 Green 0 086 44 Orange 30DR BFLT24 0 1405 28 Yellow 0 089 43 Black MINIMUM...

Page 3: ...th the vent pointing down as shown in Figure 2 Pointing the vent down protects it from freezing rain or sleet WARNING Never connect natural gas appliance to private non utility gas wells This gas is com monly known as wellhead gas CAUTION Use only new black iron or steel pipe Internally tinnedcoppertubingmaybeusedincertain areas Check your local codes Use pipe of 1 2 diam eter or greater to allow ...

Page 4: ...nected 3 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect log set and equipment shutoff...

Page 5: ...low Adjustment Screw Figure 9 Installing Inlet Fitting and Gas Connector Tube Gas Control Valve Gas Inlet Fitting Gas Connector Tube Inlet Opening INSTALLATION Continued Figure 10 Installing Cover Control Knob and Piezo Ignitor Piezo Ignitor Control Rod Extension Screw Valve Cover Control Knob Thermocouple Ignitor Pilot 5 Thread the gas supply adaptor to the fireplace gas supply pipe Adjust to mos...

Page 6: ...LOW ADJUSTMENT After installation is complete and the unit has been ignited it may be necessary to adjust the pilot Use a small flat head screwdriver to turn the flow adjustment screw on the manual control valve see Figure 14 Turn the screw counterclockwise to allow more gas to flow or clockwise to restrict gas flow Be careful to limit the turns to 2 1 2 from the fully closed position Further turn...

Page 7: ...es not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat steps 3 through 7 If control knob does not pop up when released contact a qualified service person or gas supplier for repairs 8 Turn contro...

Page 8: ...e in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products LLC P N 126905 01 Rev B 11 2016 1508 Elm Hill Pike Suite 108 Nashville TN 37210 fire parts com ...

Reviews: