GA9050A-1 SERIES ON/OFF SAFETY VALVE/PILOT KIT ASSEMBLY

Natural Gas Installation

1.  Thread the gas control valve onto the burner inlet fitting (see 

Figure 7). Use thread sealant on the male threads of the burner 

inlet fitting. Hold the burner inlet fitting with a wrench to prevent 

overtightening the connection to the burner. Make sure the control 

rod is facing the front (see Figure 7).

2.  Attach the pilot gas line to the pilot outlet of the gas control valve 

and tighten. Connect the thermocouple to the rear of the gas 

control valve. See Figure 8. Do not overtighten. If using propane/

LP gas, see

 Changing Pilot Orifice

, page 6.

3.  Install the inlet fitting into the inlet opening of the gas control valve 

(see Figure 9). Use thread sealant on the male pipe threads.

4.  Place the burner pan assembly in the center of the fireplace floor. 

Make sure the front of pan faces forward.

Figure 7 - Installing Gas Control Valve

Figure 8 - Gas Control Valve with Thermocouple and Pilot 

Burner Inlet Fitting 

(containing orifice)

Gas Control Valve

Burner Pan 

Assembly

Control 

Rod

Thermocouple and 

Line

Pilot and Line

Gas Control Valve

Pilot Flow 

Adjustment Screw

Figure 9 - Installing Inlet Fitting and Gas Connector Tube 

Gas Control Valve

Gas Inlet 
Fitting

Gas Connector 
Tube

Inlet Opening

INSTALLATION  

Continued

Figure 10 - Installing Cover, Control Knob, and Piezo Ignitor

Piezo 

Ignitor

Control Rod 
Extension

Screw

Valve 

Cover

Control 

Knob

Thermocouple

Ignitor

Pilot

5.  Thread the gas supply adaptor to the fireplace gas supply pipe. 

Adjust to most convenient position.

6.  Install the gas connector tube to the gas supply adaptor. Carefully 

shape tube and attach to gas inlet fitting (see Figure 9). Be careful 

not to cause kinks in tube.

7.  Test for leaks following instructions in your hearth kit owner’s 

manual under the section 

Testing Burner for Leaks

.

8.  Retighten and adjust the location of the gas control as necessary. 

The gas control should be level, with the control rod to the front. 

9.  Install cover to burner pan using screws provided.
10. Install thermocouple, pilot, and ignitor onto valve cover as shown 

in Figure 10. Use the provided screws. 

11. Push the control rod extension onto the “D” shaped control rod 

through the center hole in the cover.

12. Install the position decal and control knob making sure to align 

the marks with the correct stop positions of the gas control. Pilot 

position will allow the knob to push in about 1/2". Align the decals 

in the pilot position. 

f i r e - p a r t s . c o m

Summary of Contents for GA9050A-1

Page 1: ...01 Pilot Valve Dial Extension 3 901080 01 Propane Conversion Decal 901691 01 P126905 01 INSTALLATION INSTRUCTIONS MANUALON OFFSAFETYVALVE PILOTKIT MODEL GA9050A 1 F0235 For All Single Dual and Triple Burner Natural and Propane LP Gas Logs WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Installation and service must ...

Page 2: ...iple Burner 65 000 55 000 8 dia BFLT24 24 Triple Burner 70 000 60 000 8 dia Add 6 if safety valve pilot is used At depth indicated FUEL INLET PRESSURE SPECIFICATIONS W C Gas Min Max NG 5 5 10 5 LP 11 13 BURNER ORIFICE NATURAL PROPANE LP LOG SIZE IN NUM CLR IN NUM CLR 18SR DR 0 120 31 Blue 0 073 49 Red 24SR DR BFLT18 0 129 30 Green 0 086 44 Orange 30DR BFLT24 0 1405 28 Yellow 0 089 43 Black MINIMUM...

Page 3: ...th the vent pointing down as shown in Figure 2 Pointing the vent down protects it from freezing rain or sleet WARNING Never connect natural gas appliance to private non utility gas wells This gas is com monly known as wellhead gas CAUTION Use only new black iron or steel pipe Internally tinnedcoppertubingmaybeusedincertain areas Check your local codes Use pipe of 1 2 diam eter or greater to allow ...

Page 4: ...nected 3 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect log set and equipment shutoff...

Page 5: ...low Adjustment Screw Figure 9 Installing Inlet Fitting and Gas Connector Tube Gas Control Valve Gas Inlet Fitting Gas Connector Tube Inlet Opening INSTALLATION Continued Figure 10 Installing Cover Control Knob and Piezo Ignitor Piezo Ignitor Control Rod Extension Screw Valve Cover Control Knob Thermocouple Ignitor Pilot 5 Thread the gas supply adaptor to the fireplace gas supply pipe Adjust to mos...

Page 6: ...LOW ADJUSTMENT After installation is complete and the unit has been ignited it may be necessary to adjust the pilot Use a small flat head screwdriver to turn the flow adjustment screw on the manual control valve see Figure 14 Turn the screw counterclockwise to allow more gas to flow or clockwise to restrict gas flow Be careful to limit the turns to 2 1 2 from the fully closed position Further turn...

Page 7: ...es not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat steps 3 through 7 If control knob does not pop up when released contact a qualified service person or gas supplier for repairs 8 Turn contro...

Page 8: ...e in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products LLC P N 126905 01 Rev B 11 2016 1508 Elm Hill Pike Suite 108 Nashville TN 37210 fire parts com ...

Reviews: