6

PRODUCT FEATURES

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system.

The ODS/pilot shuts off the heater if there is not enough fresh air and cuts off main burner gas in the 

event of flame out.

ELECTRONIC PUSH BUTTON IGNITION SYSTEM

This heater is equipped with an electronic push button ignition system. This system requires

one AAA battery (provided).

LEG KIT

2 legs and 4 mounting screws are included for floor mounting the heater.  See page 13.

PIEZO IGNITION SYSTEM (SELECT MODELS)

This heater is equipped with a piezo electric ignition system.

THERMOSTAT HEAT CONTROL(SELECT MODELS)

The control automatically cycles the burner on and off to maintain a desired room

temperature. See page 24.

FAN KIT(SELECT MODELS)

The fan kit helps to distribute the warmed air into the space more rapidly.

  State of Massachusetts: 

The installation must be made by a licensed plumber or gas fitter in 

  the Commonwealth of Massachusetts. Sellers of unvented propane or natural gas-fired 

  supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale 

  of the unit.

  In the State of Massachusetts, unvented propane or natural gas-fired space heaters shall 

  be prohibited in bedrooms and bathrooms.

  In the State of Massachusetts the gas cock must be a T-handle type. The State of 

  Massachusetts requires that a flexible appliance connector cannot exceed three feet

  in length.

LOCAL CODES

Install and use heater with care. The installation must conform with local codes or, in the absence of 

local codes, with the latest edition of The Nation Fuel Gas Code, ANSI Z223.1/NFPA 54

*Available from:

American National Standard Institute, Inc. 

 National Fire Protection Association, Inc.

1430 Broadway  

 

 

 

 

1 Batterymarch Park

New York, NY 10018  

 

 

 

Quincy, MA 02269-9101

This heater is designed for vent-free operation. State and local codes in some areas prohibit, restrict 

and or have special requirements for vent-free heaters.

Summary of Contents for (C)(GC)IR6PMA series

Page 1: ...ch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier c...

Page 2: ......

Page 3: ...Electronic Push Button Manifold Pressure 10 in W C 10 in W C Inlet Gas Pressure Maximum 14 in W C 14 in W C Minimum For purposes of input adjustment 11 in W C 11 in W C Dimensions in H x W x D Height...

Page 4: ...MA MAX BTU 6 000 12 000 Fuel Type Natural Gas Natural Gas Ignition Electronic Push Button Electronic Push Button Manifold Pressure 5 in W C 5 in W C Inlet Gas Pressure Maximum 14 in W C 14 in W C Mini...

Page 5: ...temperatures locate this appliance out of traffic and away from furniture and draperies This appliance is intended for supplemental heating CARBON MONOXIDE POISONING Early signs of carbon monoxide po...

Page 6: ...r shuts off do not relight until you have provided fresh outside air If heater keeps shutting off have it serviced 6 Do not run heater Where flammable liquids or vapors are used or stored Under dusty...

Page 7: ...n must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a cop...

Page 8: ...ry 1 000 BTUs 3 Kw of gas input per hour An unvented room heater is intended as a supplemental heater rather than a primary heat source In most supplemental heat applications the water vapor does not...

Page 9: ...unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are...

Page 10: ...TU hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct...

Page 11: ...fresh air by using ventilation grills or duct You must provide two permanent openings one within 12 in of the ceiling and one within 12 in of the floor Connect these items directly to the outdoors or...

Page 12: ...stalling heater next to vinyl or cloth wall coverings or operating heater where impurities such as tobacco smoke candles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to d...

Page 13: ...d heater must be disconnected from gas supply and removed from wall before installing fan accessory Contact a qualified service person to do this 2 Remove fan access panel by removing 4 panel screws u...

Page 14: ...f heater extending outside the table edge 2 Fasten Legs to heater using Support Leg Screws Fig 13 Note If the heater is to be installed directly on carpet ing tile or other combustible material other...

Page 15: ...crew Locations 1 Tape mounting bracket to wall where heater will be located Make sure mounting bracket is level 2 Mark screw locations on wall See Fig 16 Note Mark only last hole on each end of mounti...

Page 16: ...ough bracket and into wall anchors 7 Tighten screws until mounting bracket is firmly fastened to wall 8 Check that the bracket is secure before mounting heater Attaching Wall Hanging Spacers to Heater...

Page 17: ...If gas line pressure is higher heater regulator damage could occur CAUTION Never connect heater directly to an LP supply This heater requires an external regulator not supplied Install the external re...

Page 18: ...3 5kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa Pres...

Page 19: ...call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS MANUAL GAS CONTROL 1 ST...

Page 20: ...h 7 Wait 1 minute before attempting to light pilot again If after several tries the pilot still goes out turn the gas control knob clockwise to the OFF position and call your service technician or gas...

Page 21: ...service agency PILOT FLAME PATTERN Fig 26 shows a correct pilot flame pattern Fig 27 shows an incorrect pilot flame pattern The incor rect pilot flame is not touching the thermocouple This will cause...

Page 22: ...flame pattern with lifting and excessive flame height If burner flame is incorrect turn heater off see To Turn Off Gas to Appliance page 19 see Troubleshooting pages 23 through 26 Fig 28 Correct Flame...

Page 23: ...d using compressed air no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions...

Page 24: ...itioned wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor or ignition module 7 Bad...

Page 25: ...r gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Mainte nance page 21 or contact customer...

Page 26: ...r 3 Clean ODS pilot see Care and Maintenance page 22 Gas odor exists even when control knob is in OFF posi tion 1 Gas leak See Warning Statement at top of page 22 2 Control valve is defective 1 Locate...

Page 27: ...s no power to the fan 2 Fan is set to AUTO 3 Fan motor is bad 1 Fan housing or blades are dirty 2 Fan rotation is blocked 3 Defective fan 1 See Cleaning Fan page 22 2 Verify wiring is not in fan path...

Page 28: ...e 1 AQ000112 AQ000112 AQ000112 AQ000112 7 Overheat Limit Switch 1 AQ000042 AQ000042 AQ000042 AQ000042 8 1 NG Regulator Assembly 1 AQ000073 AQ000073 AQ000073 AQ000073 8 2 LP Regulator Assembly 1 AQ0000...