background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

7

INNOVATIVE HEARTH PRODUCTS

  •

  LINEAR ELECTRIC FIREPLACE

  •

  INSTALLATION INSTRUCTIONS

The On/Off Switch is located on the right 

side of the unit below the Heater Cutoff 

Access Panel. In the recessed install 

option, this switch must be turned into 

the "ON" position and the appliance 

must be controlled with the remote 

provided.

Note: Ensure the circuit breakers for the power 

supply are turned on.

This appliance can be activated using the fire-

place and heater On/Off Switch  (see 

Figures 7 

& 8

)

 or by using the remote control when the 

unit power switch is already in the "ON" position.

The manual controls are located on the firebox 

floor on the front left (see 

Figure 5

)

. If an 

optional glass enclosure is installed, it must 

be removed to access.

MAINTENANCE

This appliance has been designed to provide 

many years of trouble-free service. The com-

ponents that will need to be serviced have been 

kept to a minimum.  Periodic dusting of the 

fireplace is all that should be required.

       WARNING 

An authorized service represen-

tative should perform any other 

servicing.

       CAUTION 

Handle glass very carefully to 

prevent accidental breakage.

       CAUTION 

Do not use abrasive cleaners on 

the glass panel. Do not spray 

liquids directly onto any surface 

of the fireplace.

       WARNING 

When cleaning the fireplace,  the 

fireplace must be cool.

CLEANING THE GLASS ENCLOSURE 

PANEL

Over time the front glass panel may become 

dirty or dusty. Dust can be removed by lightly 

rubbing the glass surface with a clean, lint free 

cloth or paper towel.  To remove fingerprints 

or other marks, use a damp cloth with a good 

quality household glass cleaner. The front glass 

panel should be completely dried with a clean, 

lint free cloth or paper towel.

       CAUTION 

Disconnect power before

attempting any maintenance or 

cleaning to reduce the risk of 

fire, electrical shock or personal 

injury. 

Figure 7

On

Fireplace and Heater On/Off

When the main power switch is turned on, 

power is supplied to the fireplace.

Off

Figure 8

Main Power Switch in "OFF" 

Position.

OPERATION

The appliance can be turned on either by the 

switch located on the lower right hand side of 

the heater body or by supplied remote control.

Manual Operation

1. The main power ON/OFF switch in position 

“O,” the heater is OFF.

2. When main power ON/OFF switch is at posi-

tion “I,” the heater is ready to use.

3. Press the HEAT button on the remote control 

repeatedly to set the heater to desired heat 

setting. 

4. Press the Flame brightness adjustment 

button to adjust the flame height and ember bed 

brightness. Press and release the FLAME control 

button to cycle through LO, MED, HI and OFF.

SAFETY CUT-OFF

•   This appliance is fitted with a safety 

cut-off which will operate if the heater 

overheats (eg. due to blocked air 

vents). For safety reasons, the heater 

will NOT automatically reset.

•   To reset the appliance, disconnect 

the appliance from the mains supply 

for at least 30 minutes. Reconnect 

the supply to the main switch on the 

appliance.

AUTO MODE

Under this mode the heater will automatically 

turn ON at high heat setting 1500w heat output 

when the room temperature drops below 72˚F 

(22˚ C). When the room temperature is between 

72-77˚F (22-25˚ C) the heater output  will switch 

to low heat set ting 1000W. When the room 

temperature goes above 77˚F (25˚ C) the heater 

will be turned off and the cycle will continue.

900264-00 Rev. NC  06/14

Summary of Contents for Arcturus54

Page 1: ...t limited to the fireplace and accessories may void the warranty listings and approvals of this system and could result in an unsafe and potentially dangerous installation Exposed surfaces of the electronic fireplace adjascent to heaters and blowers may become hot Care should be taken to avoid contact with blower heat discharge outlets such as the one on the top of this fireplace WARNING If the in...

Page 2: ...NTENDED FOR USE IN BATHROOMS LAUNDRY AREAS OR SIMILAR INDOOR LOCA TIONS NEVER LOCATE THIS APPLI ANCE WHERE IT COULD FALL INTO A BATHTUB OR OTHER WATER CON TAINER DO NOT RUN ELECTRICAL WIRING OR POWER CORD UNDER CARPETING OR COVER WITH THROW RUGS RUNNERS OR SIMILAR MATERIALS FOR 120 VAC POWER CORD AVOID THE USE OF AN EXTENSION CORD BECAUSE THE EXTENSION CORD MAY OVERHEAT AND CAUSE A RISK OF FIRE HO...

Page 3: ... 15 PACKAGING LIST This assembled Electric Room Heater is packaged with One accessory package located in the firebox containing 1 One Installation and Operation Manual 2 One Warranty Certificate in manual 3 One Remote Control GENERAL INFORMATION Power Supply Wire Specifications 120 Volt 60 Hz 1500 Watts Power is supplied to the fireplace through a 120Volt 60Hz receptacle located withing reach of t...

Page 4: ... heat NOTE Minimumdistancesbetweenwalls floors and ceilingsmustbeobserved SeeFigure2 Failuretodo so may result in damage to finishing materials on the wall including but not limited to paint and wallpaper These Electric Fireplaces offer a recessed instala tion see Figure 3 that gives the fireplace a more distinguished appearance Recessed framing places the front glass on the unit nearly flush with...

Page 5: ...ents 120 Volt 60 Hz Rated Wattage 1600 Watts Amperage 13 33 Amps Blower CFM 83 CFM 120 V 5 461 BTU HR b Once the screws are out the top metal bracket will come loose place the bracket away Make sure the glass is supported while doing this Lift the glass up and out from the heater body c Place the crystals along the light unit in desired position d Put the front glass back and place the metal brack...

Page 6: ... the wiring to the fireplace as shown on Page 14 4 Performafunctiontest SeeFireplaceHeater On Off on Page 7 and Remote Control Operation on Page 8 5 Turn the master power switch to the Off position and cut the power to the breaker leading to the appliance RECESSED INSTALLATION OPTION Use the following detailed instructions for recessed installation Installing the fireplace is a two person job 1 Pr...

Page 7: ...her marks use a damp cloth with a good qualityhouseholdglasscleaner Thefrontglass panel should be completely dried with a clean lint free cloth or paper towel CAUTION Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire electricalshockorpersonal injury Figure 7 On Fireplace and Heater On Off When the main power switch is turned on power is supplied to the firep...

Page 8: ...espond to the transmit ter Do not PRESS the buttons more than once within two seconds for correct operation 3 PowerOnpowerbutton Thepower onbutton at top left corner of the remote is the main ON OFFpower button Thiswillturnoffallthefunc tions and the heater will be in standby mode 4 FlamePowerOnbutton Thisbuttoncontrols both the amber and blue color flame Press this buttononcetoturnONtheflameeffec...

Page 9: ...EAR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS 54 1372mm 4 3 4 120mm 22 7 16 596mm 20 508mm 54 LINEAR ELECTRIC FIREPLACE 4 3 4 120mm 22 7 16 596mm 20 508mm 54 1372mm 20 508mm 54 1372mm 4 3 4 120mm 20 508mm 54 1372mm 4 3 4 120mm 22 7 16 596mm 20 508mm 900264 00 Rev NC 06 14 ...

Page 10: ...m 2 50mm 6mm 1 5mm 12 4 mm 1 20mm MOUNTING BRACKET mm 4 3 4 120mm 22 7 16 596mm 20 508mm 7 1 16 195mm 53 1347mm 60 1524mm 4 1 4 120mm 22 7 16 569 5 3 16 132mm 20 436mm 9 5 8 244mm 17 1 8 436mm 7 1 16 195mm 53 1347mm 60 1524mm 4 1 4 120mm 22 7 16 56 5 3 16 132mm 20 436mm 9 5 8 244mm 17 1 8 436mm 7 1 16 195mm 53 1347mm 60 1524mm 4 1 4 120mm 5 3 16 132mm 20 436 17 1 8 4 900264 00 Rev NC 06 14 ...

Page 11: ...ember bed is not glowing LED strip failure or wiring is loose Qualified service technician Inspect all wiring for loose connec tions and repair or replace if neces sary Inspect LED strips and replace if necessary 5 Flame sputters Flame motor is defective Qualified service technician Replace flame motor 6 Remote control does not work Low batteries Unit switch and or wall switch in on position Homeo...

Page 12: ...sembly F2046 1 13 Plastic Handle N A 1 14 Left Side Panel N A 1 15 Left Inner Lining Board N A 1 16 Upper Bar N A 1 17 Upper Panel N A 1 18 Remote Receiver Assembly F2048 1 19 Air Outlet Bracket N A 1 20 Heater Assembly F2049 1 21 Circuit Control Board F2050 1 22 Firebox N A 1 23 Right Lining Panel N A 1 24 Right Side Panel N A 1 25 Heater Cutoff Access Panel N A 1 26 Rocker Switch F2051 1 27 Powe...

Page 13: ...DIAGRAMS ILLUSTRATIONS NOT TO SCALE 13 INNOVATIVE HEARTH PRODUCTS LINEAR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS EXPLODED DIAGRAM WITH AVAILABLE REPLACEMENT PARTS 54 AND 60 MODELS 900264 00 Rev NC 06 14 ...

Page 14: ... 104 C5 104 R5 10K LED1 D1 T1 SS8050 R 180 DS LED3 DS LED2 R 180 1 2 LED HY 2 4 2 1 2 FIRE B 2 4 2 LED6 LED5 T2 SS8050 100 LED8 LED7 R 100 1 2 LED HB 2 4 2 1 2 FIRE Y 2 4 2 12V 12V 12V FAN MOTOR 6 P0 2 7 C4 C6 5v 25V 47uF 104 HS0038 BUZ1 D1 4007 T3 SS8050 R4 510 5V R2 1K R9 510 LED6 LED5 T4 SS8050 180 LED8 LED7 R 100 1 2 LED M 2 4 2 1 2 LAMP 2 4 2 12V 12V 12V C13 400V 22U 6mH L2 AC 1 V 2 AC 3 V 4 ...

Page 15: ...ted to normal use All precautions and warnings as described in the instruction owner s manual must be followed c damages caused by failing to provide proper maintenance and service in accordance with the instruc tions provided with the Product d damages repairs or inefficiency resulting from faulty installation or application of the Product This Limited One Year Warranty covers only parts and labo...

Page 16: ...900264 00 Rev NC 06 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 IHP us com P900264 00 INNOVATIVE HEARTH PRODUCTS LINEAR ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS ...

Reviews: