Contraindications

DO NOT use on the injured area.
DO NOT use if allergic to stainless steel or ABS plastic.

Safety Warnings

(1) About measurement

1. For human body temperature measurement only.
2. Predict Mode for oral use only. If you want to use in other 

positions, such as axillary or rectal, please refer to the section 
of the Monitor Mode or consult your physician. Incorrect 
operation may cause inaccurate measurement results and 
injuries.

3. Thermometer readings should be regarded as a reference. 

DO NOT attempt self-diagnostics or self-treatment using the 
temperature readings. Please seek professional medical 
advice when necessary.

4. There is no absolute standard for human body temperature. 

Knowing your own normal body temperature range is 
important to accurately determine if you have a fever.

5. Patients should not bathe, drink hot or cool water, eat, or be 

physically active for 30 minutes before taking a reading. 
Temperature readings taken when a body is in a state of 
stable equilibrium is more accurate and useful as a reference.

6. DO NOT measure body temperature immediately after 

consuming a drug that raises body temperature. Tempera-
ture readings taken at this time will not be accurate.

7. DO NOT measure body temperature in an environment with 

strong EM interference (examples include places close to a 
working microwave, induction cooker, or cellphone in-use) as 
EM interference may cause errors in the reading or even 
device failure.

8.  This product should be considered a personal device. Clean 

and sanitize the product properly  before use to prevent 
cross-contamination.

9. Make sure babies and children do not operate the thermom-

eter on their own, incorrect usage may result in injury 
without proper adults’ supervision.

10.Do not take temperature measurement over scar tissue, 

open sores or abrasions.

11.This thermometer conforms to all of the requirements 

established in ASTM standard E1112.Full responsibility for 
conformance of this product to the specification is assumed 
by (manufacturer: ANDON HEALTH CO., LTD. Add: No. 3 
Jinping Street, Ya An Road, Nankai District, Tianjin 300190, 
China).

9. Waterproofness: probe portion only.
10. Operating conditions: 
     Temperature: 41

℉ 

- 104

(5

-40

)

     Humidity: 15% ~ 95% RH, non-condensing
     Atmospheric Pressure: 70kPa ~ 106kPa
11. Transportation and storage conditions: 
     Temperature: -4

 ~ 

 

+131

(-20

-55

)

     Humidity: 15% ~ 95% RH, non-condensing
     Atmospheric Pressure:  50kPa ~ 106kPa

2

Summary of Contents for PT1

Page 1: ...afety Warnings Troubleshooting Care Maintenance Box Contents Signs Symbols Electronic Compatibility Information Warranty 1 1 1 2 2 4 6 6 7 7 8 9 1 Replacing Battery 5 Instruction for Use 3 9 Clinical...

Page 2: ...632 DC 3 0V button battery 3 Resolution 0 1 0 1 4 Device dimensions 128mm 28mm 13mm 5 Screen dimensions 29mm 15mm 6 Net weight 18g battery included 7 Measurement range 89 6 109 4 32 43 appears when be...

Page 3: ...nsuming a drug that raises body temperature Tempera ture readings taken at this time will not be accurate 7 DO NOT measure body temperature in an environment with strong EM interference examples inclu...

Page 4: ...thermometer is a precise instrument Please properly store in the protective case after use to prevent unnecessary damage 2 DO NOT tread or bend the thermometer which may cause product damage 3 Make su...

Page 5: ...s for remeasurement 4 1 Make sure the thermometer is in the OFF mode 2 Hold the button until ONLY and symbols flash on the right corner of the screen approximately 8 seconds Then release the button im...

Page 6: ...r with the finger and apply some force to slide the cover backwards to open the battery compartment 2 Remove the old battery 3 Refer to the battery polarity symbols to orient the new battery properly...

Page 7: ...the thermometer If the thermometer is very dirty the cloth can be moistened with some Isopropyl alcohol to clean the device 3 Do not use sonicleaning or strong waterspout to clean the thermometer 4 Do...

Page 8: ...nstruments must be disposed of in accordance with the locally applicable regulation not with domestic waste 0197 Serial number IP code of the device this device s grade of against ingress of solid for...

Page 9: ...environment 385 450 710 745 780 810 870 930 1720 1845 1970 2450 5240 5500 5785 380 390 430 470 704 787 800 960 1700 1990 2400 2570 5100 5800 Pulse modulation 18Hz 27V m FM 5kHzdeviation 1kHzsine 28V...

Page 10: ...third parities Damage which has arisen during transport from the manufacturer to the consumer or during transport to the service centre Accessories which are subject to normal wear and tear The device...

Reviews: