The monitor will not work until the battery has enough power.
• When the monitor needs charging, please connect the monitor to a power source.
• You should charge the battery when the battery is less than 25% charged. Overcharging the
battery may reduce its lifetime.
• When in charging mode, the charging status will be displayed on the LED screen. See the table
below for details.
Do not change the battery. If the battery can no longer be charged, please contact Customer Service.
Overcharging the battery may reduce its lifetime.
Lithium battery replacement by inadequately trained personnel could result in a hazard such as
a fire or explosion.
Do not plug or unplug the power cord into the electrical outlet with wet hands. If the AC
adapter is abnormal, please change the adapter.
Do not use the monitor while charging.
Do not use any other type of AC adapter as it may harm the monitor.
The monitor, cable, battery and cuff must be disposed of according to local regulations at
the end of their usage.
Note:
The battery has limited charge cycles and may eventually need to be replaced by an iHealth
service provider. Battery life and charge cycles vary by use and settings.
TROUBLESHOOTING
Monitor Status
Charging
Fully charged
Battery charge <25%
Battery low
Status Indicator
battery/charge symbol flashing slowly
battery/charge symbol steady
battery/charge symbol flashing fast
battery/charge symbol flashing fast
13
Summary of Contents for Neo
Page 53: ...EN Smart Blood Pressure Monitor 1 1 1 1 2 2 3 4 5 7 9 10 12 13 15 16 17 18 19 20...
Page 74: ...Table 3 Proximity fields from RF wireless communications equipment 21...
Page 75: ...Table 4 Input a c power Port 22...
Page 178: ...iHealth BP5S AR 1 1 1 2 3 3 4 4 6 8 9 12 16 18 21 22 23 25 27 28...
Page 179: ...iHealth Neo iHealth Neo 1 iHealth Neo 1 1 1 1 iHealth Neo 22 42 8 6 16 5 1...
Page 180: ...2...
Page 181: ...M 3...
Page 183: ...a iHealth MyVitals QR b Neo BP 5 S Select New Device c START M 000 d e 5...
Page 184: ...6...
Page 185: ...a b 1 2 c d e 1 7...
Page 186: ...1 2 1 2cm 1 2 1 2cm 2 3 4 5 200 a START LCD 8...
Page 188: ...a M M M 10 START b M 000 1 iHealth Neo 10...
Page 190: ...15 20 55 4 131 16 90 17 80 105 18 130 19 LED 1 2 A V 12...
Page 191: ...3 4 5 IHB IHB iHealthMyVitals IHB 1 CV 25 2 0 14 53 6 7 13...
Page 193: ...13 14 15 16 17 18 19 20 21 15...
Page 194: ...LED iHealth MyVitals 25 25 LED 16...
Page 195: ...25 iHealth 17...
Page 196: ...LED Er0 LED Er1 LED Er2 LED Er3 LED Er4 LED Er5 300 LED Er6 160 15 18...
Page 197: ...LED Er7 LED Er8 LED ErA LED Er Bluetooth START 10 19...
Page 198: ...LED Bluetooth Bluetooth iOS Android START 10 iOS Android START 10 20...
Page 199: ...1 2 3 4 5 10 000 1000 6 300 7 75 90 8 9 6 20 21...
Page 200: ...10 6 20 11 iHealth iHealth iHealth Labs Inc IHealth iHealth iHealth 22...
Page 201: ...iHealth 1 2 iHealth iHealth iHealth BF 23...
Page 204: ...IC RSS 210 IC RSS 1 CE CE ANDON HEALTH CO LTD 26...
Page 206: ...Bluetooth 2M ISM 2 4 GFSK 20 1 CISPR 11 1 IEC 61000 3 2 IEC 61000 3 3 28...
Page 210: ...0 T U 0 5 0 45 90 135 180 225 270 315 0 T U 1 70 T U 25 30 0 IEC 61000 4 11 0 T U 250 300 32...