background image

W58 for IGT AIC2-5T000, GST 2/3/3H 

IGT Testing Systems, P.O.Box 12688, 1100 AR Amsterdam, The Netherlands / Keienbergweg 25, 1101 EX Amsterdam, The Netherlands 

Phone +31 (0)20 409 9300, Fax +31 (0)20 697 4842, E-mail: [email protected]  Internet: www.igt.nl

 

 
6.

 

For GST only: 
6.1.

 

Make a print, keep pressed both side buttons to move 
the sector into the starting position again and release 
the side buttons. NOTE: From the moment of printing 
the timer starts counting down from 10 s to 0 s. 

6.2.

 

Directly turn the disc into the position that the seam of 
the blanket is toward the sector. 

6.3.

 

Before the timer in the display has reached 0 s, press 
the side buttons. As soon as the timer has count down 
to 0, a print is made and the sector is moved into the 
starting position; at this moment release the side 
buttons. NOTE: From the moment of printing the timer 
starts counting down from 10 s to 0 s. 

6.4.

 

Repeat the points 6.2 and 6.3 for three times. NOTE: in 
the display the number of prints can be read. 

6.5.

 

Press “Enter” to finish the test for this test sample. 

7.

 

Remove the test strip from the sector. 

8.

 

Measure the test result as described in the chapter 
“Assessment”. 

9.

 

Take the printing disc from the shaft and clean it with rags 
and naphtha. 

10.

 

Clean the rollers of the inking unit or use the next segment 
for the following test. 

11.

 

Repeat points 1 thru 10 for every test strip. It is 
recommended to perform the test at least 3 times per sample. 

12.

 

After having finished the tests, clean and store all parts as 
described in the manuals.  

13.

 

Make an accurate record of the conditions and the results of 
the test. 

 
Assessment:
1.

 

VISUALLY 
Compare the printing results with a self made scale or 
compare with the results of other papers and give a number 
or description of the result. 

 
2.

 

IMAGE ANALYZING 

 

Measure the printing result with the PTS DOMAS Image 
Analyzing System, module Print Unevenness. 

 

Notes:

 

1.

 

The test results of the AIC2-5T2000, AIC2-5 and Global 
Standard Testers 2, 3 and 3H compare well with one another 
on the condition that the tests have been carried out under 
the same testing conditions.  

 
2.

 

The maximum storage life of the Mottle test ink in the 
original, closed packing is 1 year; in an opened packing 3 
months. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 In comparison to older IGT leaflets, this leaflet is valid for the  

AIC2-5T2000 and Global Standard Testers as mentioned 

 

This information leaflet has been compiled with the utmost care. However, 
may you find any inadequacies or if there are any comments, we kindly 
request you to send these to IGT Testing Systems, Sales Department. 

Reviews: