12- MANUAL MODE
Manual mode can be activated by pressing at the same time
‘UP’ and ‘DOWN’ keys
on unit display for 3 seconds (A001).
In Manual mode it is possible to select:
Dimmer level selectable by user as on DMX channel 2 (DIMMER).
Default = 255
Shutter level selectable by user as on DMX channel 1 (SHUTTER).
Default = 15
Zoom excursion from min to max as on DMX channel 5 (ZOOM).
Default = 128
Esc from Manual mode
When Manual mode is active, unit switch OFF/ON cycle will maintain Manual Mode
selection.
In Manual mode the DMX signal is ignored.
13- ERROR MESSAGES
ERROR SHOWED ON DISPLAY
APPEARS WHEN
LED thermal sensor damaged (open or in
short circuit).
Unit immediately goes in black-out.
LED temperature detected over 100°C.
Unit immediately goes in black-out.
LED Driver PCB thermal sensor damaged
(open or in short circuit).
Unit immediately goes in black-out.
LED Driver PCB temperature detected
over 100°C.
Unit immediately goes in black-out.
Zoom motor position error