background image

Safety instructions

This device is intended for use as an electronic lighting effect by means of LED tech‐

nology. The device is designed for professional use and is not suitable for use in

households. Use the device only as described in this user manual. Any other use or

use under other operating conditions is considered to be improper and may result in

personal injury or property damage. No liability will be assumed for damages

resulting from improper use.
This device may be used only by persons with sufficient physical, sensorial, and intel‐

lectual abilities and having corresponding knowledge and experience. Other persons

may use this device only if they are supervised or instructed by a person who is

responsible for their safety.
Extend the life of the device by regular breaks in operation and avoid switching it on

and off frequently. This device is not suitable for continuous use.

DANGER!
Danger for children
Ensure that plastic bags, packaging, etc. are disposed of properly and

are not within reach of babies and young children. Choking hazard!
Ensure that children do not detach any small parts (e.g. knobs or the

like) from the unit. They could swallow the pieces and choke!
Never let children unattended use electrical devices.

DANGER!
Hazardous voltage
The wiring, as well as all maintenance and repair work on the electrical

installation of the device must only be performed by qualified electrical

personnel. Failure to do so may result in electric shock and risk of fire

and loss of life.
Before starting work on the electrical installation, the device must be

turned volt-free.

DANGER!
Electric shock caused by high voltages inside
Within the device there are areas where high voltages may be present.

Never remove any covers.
There are no user-serviceable parts inside.
Do not use the device if covers, protectors or optical components are

missing or damaged.

Intended use

Safety

Safety instructions

 

Co6 LED Flood IP65 270W RGBW

7

LED floodlight

Summary of Contents for Co6 LED Flood IP65 270W RGBW

Page 1: ...Co6 LED Flood IP65 270W RGBW LED floodlight User manual ...

Page 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Straße 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 07 02 2019 ID 443193 V2 ...

Page 3: ...e 21 7 2 3 Operating mode Stand alone 21 7 3 Menu overview 22 7 4 Functions in 2 channel DMX mode 23 7 5 Functions in 3 channel DMX mode 1 24 7 6 Functions in 3 channel DMX mode 2 25 7 7 Functions in 4 channel DMX mode 25 7 8 Functions in 12 channel DMX mode 25 7 9 Functions in 14 channel DMX mode 26 7 10 Functions in 26 channel DMX mode 29 8 Technical specifications 32 9 Plug and connection assig...

Page 4: ...4 Co6 LED Flood IP65 270W RGBW LED floodlight ...

Page 5: ...ation and details on the following points Download This manual is also available as PDF file for you to download Keyword search Use the search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultation For personal consultation please contact our technical hotline...

Page 6: ...ed WARNING This combination of symbol and signal word indicates a possible dangerous situation that can result in death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a possible dangerous situation that can result in mate rial and environmental damage if it is not avoided Warning signs Type of danger Warning high voltage Warning dangerous optical...

Page 7: ... for continuous use DANGER Danger for children Ensure that plastic bags packaging etc are disposed of properly and are not within reach of babies and young children Choking hazard Ensure that children do not detach any small parts e g knobs or the like from the unit They could swallow the pieces and choke Never let children unattended use electrical devices DANGER Hazardous voltage The wiring as w...

Page 8: ...n Do not install the device near any direct heat source Keep the device away from naked flames NOTICE Power supply Before connecting the device ensure that the input voltage AC outlet matches the voltage rating of the device and that the AC outlet is pro tected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly injure the user Unplug the device...

Page 9: ...erating the LEDs with the lowest possible brightness Equipment with protection class IP65 are dust tight and completely protected against contact first code number They are also protected against splash water from any angle second code digit That is why this equipment can also be used out doors Event technology equipment is generally only designed for temporary use however event lighting and not f...

Page 10: ...n complies with the standards and rules that apply in your country Always secure the device with a secondary safety attachment such as a safety cable or a safety chain When using the diffusion filter the barndoor must be mounted above it At this all four locking pins of the barndoor must be fully engaged Secure the barn door with a safety cable on the spotlight after installa tion The safety cable...

Page 11: ...adapters are to be attached The safety rope must pass through the notches on the bottom case as shown in the following figure You can install the unit in hanging or standing position When in use the device must always be attached to a solid surface or an approved truss Always work from a stable platform whenever installing moving or servicing the unit In doing so the area underneath the unit must ...

Page 12: ...of the last DMX device in the daisy chain is terminated with a resistor 110 Ω W When you configure a group of devices in master slave mode the first unit will con trol the other units This function is ideal when you want to start a show immediately Connect the DMX output of the master device to the DMX input of the first slave device Then connect the DMX output of the first slave device to the DMX...

Page 13: ...rane button MODE Activates the main menu and toggles between menu items Closes an opened submenu UP Navigates upwards in a menu list Increases the displayed value by one DOWN Navigates downwards in a menu list Decreases the displayed value by one ENTER Selects an option of the respective operating mode confirms the set value Overview Connections and controls Co6 LED Flood IP65 270W RGBW 13 LED flo...

Page 14: ... incoming Power Twist IP65 7 POWER OUT Connection supply voltage outgoing Power Twist IP65 8 DMX OUT DMX output IP65 design 9 DMX IN DMX input IP65 design Rear panel Connections and controls 14 Co6 LED Flood IP65 270W RGBW LED floodlight ...

Page 15: ...ply to start operation After a few seconds the display indicates that a reset is in progress The device is then ready for use The dis play shows the operating mode that was selected when the unit was last powered off Operating Co6 LED Flood IP65 270W RGBW 15 LED floodlight ...

Page 16: ...enu Menu level 2 Menu level 3 Menu level 4 Meaning DMX Address Set DMX address 001 512 Setting the DMX address MODE DMX Signal Select Selection of the DMX transmission type DMX DMX via cable Wireless DMX DMX via radio transmission DMX Mode Selecting a DMX mode DMX 2Ch 2 channel DMX mode DMX 3Ch1 3 channel DMX mode 1 DMX 3Ch2 3 channel DMX mode 2 DMX 4Ch 4 channel DMX mode DMX 12Ch 12 channel DMX m...

Page 17: ...n strobe Red 0 255 Intensity red 0 to 100 Green 0 255 Intensity green 0 to 100 Blue 0 255 Intensity blue 0 to 100 White 0 255 Intensity white 0 to 100 Rainbow Rainbow effect 0 5 Effect off 6 21 Rainbow effect 1 22 37 Rainbow effect 2 38 53 Rainbow effect 3 54 69 Rainbow effect 4 70 85 Rainbow effect 5 86 101 Rainbow effect 6 102 117 Rainbow effect 7 118 133 Rainbow effect 8 134 149 Rainbow effect ...

Page 18: ...5 131 155 Automatic show 6 156 180 Automatic show 7 181 205 Automatic show 8 206 230 Automatic show 9 231 255 Automatic show 10 Auto speed 0 255 Running speed auto matic show increasing Auto Fade 0 255 Fade speed for auto matic shows Color Macro Pre defined colour Red Red Amber Amber Yellow Amber Yellowish amber coloured Yellow Yellow Green Green Turquoise Turquoise Cyan Cyan Blue Blue Lavender La...

Page 19: ... Linear Exp Exponential Log Logarithmic S Curve S shaped Dimmer Response Dimmer characteristic LED Dimmer characteristic LED 3 s delay Halogen Dimmer characteristic Halogen 5 s delay LED Frequency 800 Hz Refresh rate of the LEDs 800 Hz 1200 Hz Refresh rate of the LEDs 1200 Hz 2000 Hz Refresh rate of the LEDs 2000 Hz 3600 Hz Refresh rate of the LEDs 3600 Hz 25 kHz Refresh rate of the LEDs 25 kHz Wh...

Page 20: ...NTER UP DOWN UP DOWN and ENTER System Info Software Ver Show firmware version of the device Temp info LED Temp Show device temperature Temp Unit Unit selection for device temperature Fahrenheit Celsius Time info Operating hours display Power on Total operating hours Last run hrs Operating hours since last power up 7 2 1 Operating mode DMX In DMX mode the display shows the set DMX mode in its top r...

Page 21: ...alone In Stand alone mode the display in its lower part shows how the device is currently set n Operating Mode AUTO Fading Automatic Fade effect n Operating Mode AUTO Jumping Automatic Jump effect n Operating Mode STATIC Freely mixable colour with optional rainbow and stro boscopic effect or automatic show n Operating Mode Color Macro Selecting a pre defined colour macro Operating Co6 LED Flood IP...

Page 22: ...7 3 Menu overview Operating 22 Co6 LED Flood IP65 270W RGBW LED floodlight ...

Page 23: ...oloured 30 37 Yellow 38 45 Green 46 53 Turquoise 54 61 Cyan 62 69 Blue 70 77 Lavender 78 85 Mauve 86 93 Magenta 94 101 Pink 102 109 Warm white 110 117 White 118 125 Cold white 126 127 Colour change halted 128 191 Colour change effect increasing speed 192 255 Colour transition effect increasing speed Operating Co6 LED Flood IP65 270W RGBW 23 LED floodlight ...

Page 24: ...acro 0 5 Blackout 6 13 Red 14 21 Amber 22 29 Yellowish amber coloured 30 37 Yellow 38 45 Green 46 53 Turquoise 54 61 Cyan 62 69 Blue 70 77 Lavender 78 85 Mauve 86 93 Magenta 94 101 Pink 102 109 Warm white 110 117 White 118 125 Cold white 126 127 Colour change halted 128 191 Colour change effect increasing speed 192 255 Colour transition effect increasing speed Operating 24 Co6 LED Flood IP65 270W ...

Page 25: ...nnel Value Function 1 0 255 Intensity red 0 to 100 LED row 1 2 0 255 Intensity green 0 to 100 LED row 1 3 0 255 Intensity blue 0 to 100 LED row 1 4 0 255 Intensity white 0 to 100 LED row 1 5 0 255 Intensity red 0 to 100 LED row 2 6 0 255 Intensity green 0 to 100 LED row 2 7 0 255 Intensity blue 0 to 100 LED row 2 8 0 255 Intensity white 0 to 100 LED row 2 9 0 255 Intensity red 0 to 100 LED row 3 1...

Page 26: ...fect with increasing speed 103 127 Strobe break effect with decreasing duration of interruptions 128 250 Strobe effect with increasing speed 251 255 Open strobe 4 0 255 Intensity red 0 to 100 5 0 255 Intensity green 0 to 100 6 0 255 Intensity blue 0 to 100 7 0 255 Intensity white 0 to 100 8 Colour macro 0 5 Blackout 6 13 Red 14 21 Amber 22 29 Yellowish amber coloured 30 37 Yellow 38 45 Green 46 53...

Page 27: ...Rainbow effect 6 102 117 Rainbow effect 7 118 133 Rainbow effect 8 134 149 Rainbow effect 9 150 165 Rainbow effect 10 166 181 Rainbow effect 11 182 197 Rainbow effect 12 198 213 Rainbow effect 13 214 229 Rainbow effect 14 230 255 Rainbow effect 15 10 Automatic show 0 5 No automatic show 6 30 Automatic show 1 31 55 Automatic show 2 56 80 Automatic show 3 81 105 Automatic show 4 106 130 Automatic sh...

Page 28: ...l 128 191 Logarithmic 192 255 S shaped 14 Special functions Settings are enabled or retained if the corresponding DMX value is held for five seconds 0 5 No function 6 63 Dimmer characteristic LED 3 s delay 64 127 Dimmer characteristic Halogen 5 s delay 128 191 Fan speed setting Silent activated 3 s delay 192 255 Fan speed setting Silent deactivated 3 s delay Operating 28 Co6 LED Flood IP65 270W RG...

Page 29: ...ffect with increasing speed 103 127 Strobe break effect with decreasing duration of interruptions 128 250 Strobe effect with increasing speed 251 255 Open strobe 4 0 255 Intensity red 0 to 100 5 0 255 Intensity green 0 to 100 6 0 255 Intensity blue 0 to 100 7 0 255 Intensity white 0 to 100 8 Colour macro 0 5 Blackout 6 13 Red 14 21 Amber 22 29 Yellowish amber coloured 30 37 Yellow 38 45 Green 46 5...

Page 30: ...Rainbow effect 6 102 117 Rainbow effect 7 118 133 Rainbow effect 8 134 149 Rainbow effect 9 150 165 Rainbow effect 10 166 181 Rainbow effect 11 182 197 Rainbow effect 12 198 213 Rainbow effect 13 214 229 Rainbow effect 14 230 255 Rainbow effect 15 10 Automatic show 0 5 No automatic show 6 30 Automatic show 1 31 55 Automatic show 2 56 80 Automatic show 3 81 105 Automatic show 4 106 130 Automatic sh...

Page 31: ... Fan speed setting Silent activated 3 s delay 192 255 Fan speed setting Silent deactivated 3 s delay 15 0 255 Intensity red 0 to 100 LED row 1 16 0 255 Intensity green 0 to 100 LED row 1 17 0 255 Intensity blue 0 to 100 LED row 1 18 0 255 Intensity white 0 to 100 LED row 1 19 0 255 Intensity red 0 to 100 LED row 2 20 0 255 Intensity green 0 to 100 LED row 2 21 0 255 Intensity blue 0 to 100 LED row...

Page 32: ...n IP65 design Power consumption 250 W Supply voltage 100 240 V 50 60 Hz Degree of protection IP65 Mounting options Hanging standing Omega bracket Dimensions W H D 390 mm 268 mm 170 mm horizontal panel Weight 8 2 kg Ambient conditions Temperature range 20 C 40 C Relative humidity 50 non condensing Outdoor housing design Floodlight Colour mixture RGBW LED type x in 1 Base housing Yes Fanless No Remo...

Page 33: ...result of an incorrect connection may be a destroyed DMX controller a short circuit or just a not working light show The unit offers a 3 pin XLR socket for DMX output and a 3 pin XLR plug for DMX input Please refer to the drawing and table below for the pin assignment of a suit able XLR plug Pin Configuration 1 Ground shielding 2 Signal inverted DMX cold signal 3 Signal DMX hot signal Introduction...

Page 34: ...ck the DMX connectors and cables for proper connection 2 Try using another DMX controller 3 Check whether the DMX cables run near or parallel to high voltage cables that may cause damage or interference to a DMX interface circuit 4 Press Mode until the display shows ADDRESS XXX If the procedures recommended above do not succeed please contact our Service Center You can find the contact information...

Page 35: ... of cleaning depends on the operating envi ronment wet smoky or particularly dirty surroundings can cause more accumulation of dirt on the optics of the device n Clean with a soft cloth using our lamp and lens cleaner item no 280122 n Always dry the parts carefully Optical lenses Cleaning Co6 LED Flood IP65 270W RGBW 35 LED floodlight ...

Page 36: ...arkings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal household waste Dispose of this device through an approved waste disposal firm or through your local waste facility When discarding the device comply with the rules and regulations that apply in your country If in d...

Page 37: ...Notes Co6 LED Flood IP65 270W RGBW 37 LED floodlight ...

Page 38: ...Notes 38 Co6 LED Flood IP65 270W RGBW LED floodlight ...

Page 39: ......

Page 40: ...Musikhaus Thomann Hans Thomann Straße 1 96138 Burgebrach Germany www thomann de ...

Reviews: