background image

!C@ OPER. TIME  

  HOLD: 10)s

 

!D@ BRAKE TIME

 

FOR HOLD: 30)m

 

!F@   FIRE UP  

 TIME:  60)m

 

!G@ CH PUMP ON 

TEMP:   35)*

 

!H@ TW PUMP ON 

TEMP:   30)*

 

!J@TW PUMP ON 

        NO )

 

!I@TW HYSTERESIS 

TEMP:    3)*

 

!L@ BLOWER POWER 

MAX:   100)%

 

!A@ OPER. TIME  

 HEAT: 10)s

!B@ BREAK TIME

 HEAT: 30)s

 

!E@ BLOW TIME

 

  MULTIPL:  2)

 

!K@TW HEATING

 

BOILER>TW C

   +10)*

 

OPERATING SETTINGS

To enter the 

OPERATING MENU

 press 

MENU

 on 

MAIN DISPLAY

  and hold it 2 seconds. 

A) Feeder operation time for 

HEAT

 - the boiler temperature 

value.

below the setting 

B) Feeder operation break time for 

HEAT

C) Feeder and blower operation time for 

HOLD

 - boiler temperature above the 

setting value. The blower operation time can be increased by the blowing 
time multiplier (E) 

 

D) Feeder and blower operation break time for 

HOLD

E)  Information  how  many  times  the  blower  operation  time 

is longer than feeder operation time at 

HOLD

. It informs about the time 

necessary for blowing the fire after boiler operation break.

F)  Time  since  the  controller  operation 

START

  during  which 

the boiler is not OFF in spite of temperature decrease 

below  the  value 

of 

BURNING OUT TEMPERATURE

 . 

  

G) CH pump start temperature

H) TW (tap water) feeding pump starting temperature 

            

I) TW (tap water) container temperature decrease necessary to start the TW 

pump. 

J) TW (tap water) feeding pump priority towards CH (central heating) pump

K) Increasing the boiler temperature value while TW container is heating up if 

this  temperature  is  too  low.  The  higher  temperature  setting  the  shorter 
heating up time.

L) Blower maximum power.

         The blower power upper limit.

IGNIS gamma v 2.15

TMK Września