IGM MRBP.424321.001UM User Manual Download Page 1

C O   L t d .   I G M - D e t e c t o r  

 

Address: 27 Engels Prospect,  
building 5, litera A 
Saint-Petersburg 
194156, Russia, 
Tel: 8 (800) 234-66-90 
Website: www.igm-pribor.ru 
E-mail: [email protected]

 

 
 
 

 

 

 
 
 
 
 
 
 
 
 

 

EMI-SSD-1M CONTROL UNIT

 

USER MANUAL 

MRBP.424321.001UM

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Saint-Petersburg 

2020 

Summary of Contents for MRBP.424321.001UM

Page 1: ...ess 27 Engels Prospect building 5 litera A Saint Petersburg 194156 Russia Tel 8 800 234 66 90 Website www igm pribor ru E mail support igm pribor ru EMI SSD 1M CONTROL UNIT USER MANUAL MRBP 424321 001...

Page 2: ...Marking and sealing 10 1 7 Packaging 11 2 Safety precautions 12 3 Correct use 13 3 1 Operating hints 13 3 2 Operating limits 13 3 3 Preparation 13 3 4 Getting started 15 4 Maintenance service 17 4 1 G...

Page 3: ...is UM is applicable to all current modifications of EMI SSD 1M Warning Study this UM before mounting and operating of EMI SSD 1M Operating not in accordance with the requirements of this UM may lead t...

Page 4: ...a higher lever system external circuits switching audio and light alarm in case of set threshold exceeding 1 1 2 EMI SSD M1 can be used as control unit within control system EMI M1 1 2 Application sc...

Page 5: ...detectors Bell 202 Current Hart 6 1 8 detectors Inaccuracy limit of permissible reduced error of current signal meas urement 4 20 mA 15 35 0 2 10 15 and 35 50 0 5 Output signals Digital output interfa...

Page 6: ...nel 4 channel 5 LORA channel 6 channel 7 channel 8 HART Figure 1 EMI SSD 1M elements isolation Notice EMI SSD 1M galvanically isolated elements graphic symbol 1 4 Construction and overall dimensions 1...

Page 7: ...7 MRBP 424321 001UM Version 1 0 27 01 2020 Figure 2 EMI SSD 1M w o LoRa antenna overall dimensions Figure 3 EMI SSD 1M with LoRa antenna overall dimensions Notice Antenna is installed depending of LO...

Page 8: ...Description and operation 8 MRBP 424321 001UM Version 1 0 27 01 2020 Figure 4 EMI SSD 1M front view Figure 5 EMI SSD 1M back view...

Page 9: ...g is carried out by 3 relays shifting can be tuned 1 5 5 EMI SSD 1M channels tuning and configuration is carried out in control unit menu by built in key pad and OLED display as well as by Bluetooth 1...

Page 10: ...ppendix A Actuators sensors communication lines and power supply are connected to these joints Split design of the terminal blocks allows to perform hot swapping SD card slot and antenna L Ra connecto...

Page 11: ...ed by non removable tags WARRANTY Seals WARRANTY locations rear cover over the location of one of the screws 1 7 Packaging EMI SSD 1M is packed in transport box of the manufacturer in compliance with...

Page 12: ...ectric installations of consumers Workplace safety rules during operation of electric installations of consumers and Regulations for Electrical Installation must be observed 2 3 Any connections to EMI...

Page 13: ...in hazardous and corrosion environment 3 2 2 Operating conditions ambient temperature 10 50 oC RH 95 w o condensation atmospheric pressure 80 120 kPa 3 3 Preparation 3 3 1 Working place preparation Wh...

Page 14: ...ivery set and connect them to the EMI SSD 1M Notice Installation of external connections is carried out with a wire with a cross section of not more than 2 5 mm2 For stranded wires use cable lugs 3 3...

Page 15: ...powering EMI SSD 1M on connection accuracy and supply voltage level should be checked if the power wires are connected incorrectly EMI SSD 1M will not function but it will not fail at a supply voltage...

Page 16: ...ype selection for each of 8 channels input of sensor position for each channel target gas selection for each channel measurement units selection for each channel measurement range selection blanking z...

Page 17: ...a DIN rail quality check external connections quality check Deficiencies found during inspection should be immediately rectified 4 2 2 2 EMI SSD 1M performance check consists in measuring channels ala...

Page 18: ...ce the battery replacement Battery replacement routine turn off the power supply of the control unit and the devices connected to it disconnect the terminals remove the control unit from DIN rail undo...

Page 19: ...correspond to conditions 5 in accordance with GOST 15150 69 at ambient temperatures from 25 to 55 in compliance with protective measures from shocks and vibrations 5 1 3 Transportation is carried out...

Page 20: ...ly supply voltage input negative contact 0 V X10 1 RS485 A noninverting driver output receiver input to the control unit 2 RS485 GND common trunk 0 V Galvanically isolated from pin power sup ply negat...

Page 21: ...21 MRBP 424321 001UM Version 1 0 27 01 2020 2 Common Fail ure failure relay common contact 3 NC Failure normally closed failure relay contact Figure A 1 Pin assignment...

Page 22: ...22 MRBP 424321 001UM Version 1 0 27 01 2020 Appendix B EMI SSD 1M connection diagram Figure B 1 EMI SSD 1M connection diagram Sensors connection to EMI SSD 1M analog inputs three wire circuit...

Page 23: ...23 MRBP 424321 001UM Version 1 0 27 01 2020 Figure B 2 EMI SSD 1M connection diagram Sensors connection to EMI SSD 1M analog inputs four wire circuit...

Page 24: ...24 MRBP 424321 001UM Version 1 0 27 01 2020 Figure B 3 EMI SSD 1M connection diagram Sensors connection via interface RS 485...

Page 25: ...RD Register address Purpose Description Access General information 0x03 0 Interface RS 485 set tings Device address bits 0 3 Exchange via channel RS 485 rate 0x01 1200 baud 0x02 2400 baud 0x03 4800 ba...

Page 26: ...nnected bit 7 1 archiving switched on 0 switched off bit 8 1 SD card record error 0 no error bit 9 1 access to settings is password protected 0 no bit 10 bit 11 bit 12 bit 13 bit 14 bit 15 R 11 Channe...

Page 27: ...x05 19200 baud 0x06 38400 baud 0x07 57600 baud bits 4 5 R Parity 0x00 None 0x01 Odd 0x02 Even bits 6 7 R Stop bit 0x01 one stop bit 0x02 two stop bits bits 8 15 R W Address 1 247 R W 34 Display menu a...

Page 28: ...according to 202 register Controller EMI SSD 1M status register 206 0 bits 0 15 0x01 LOADER LOGIN 0x02 SOFTWARE UNDATED 0x03 SOFTWARE UPDATING ERROR 0x04 ALL SETTINGS RESET 0x14 REBOOT 0x17 POWER OFF...

Page 29: ...f bit 5 Channel 6 1 switch on 0 switch off bit 6 Channel 7 1 switch on 0 switch off bit 7 Channel 8 1 switch on 0 switch off bits 8 15 reserve R W Channels data 0x03 Internal channels 1 8 300 Channel...

Page 30: ...0x39 9 0x41 A 0x5A Z R W 703 Channel 1 Position symbols 3 4 Low byte Symbol 4 High byte Symbol 3 Values 0x2D 0x30 0 0x39 9 0x41 A 0x5A Z R W 704 Channel 1 Position symbols 5 6 Low byte Symbol 6 High b...

Page 31: ...e can t be more than or equal to maximal value more than or equal to threshold 1 value more than or equal to threshold 2 value R W 710 Channel 1 Maximal value 10 accuracy register 708 bits 6 7 0 65535...

Page 32: ...r threshold 2 R W 715 Channel 1 Hysteresis threshold 2 value 10 accuracy register 708 bits 6 7 0 65535 Limitations hysteresis value can t be more than or equal to threshold 2 value R W 716 Channel 1 T...

Page 33: ...51313 99 Benzene 14 Heptane 7 16 46 Kerosene 52050 06 Kerosene 15 Propylene 3 6 47 PID2 PID2 16 Ethanol 2 5 48 PID3 PID3 17 Toluene 6 5 3 49 Isopentane i C5H12 18 Benzene 6 6 50 Ethylene oxide C2H4O...