Disconnecting power supply. 

Turn the switch off, disconnect the 

dust collector from the power supply, and allow the impeller to come to 

a complete stop before leaving the machine unattended or doing any 

service, cleaning, maintenance, or adjustments.

Suspended dust particles and ignition sources. 

Do not operate the 

dust collector in areas were explosion risks are high. Areas of high risk 

include, but are not limited to, areas near pilot lights, open flames, or other 

ignition sources.

Fire suppression. 

Only operate the dust collector in locations that contain 

a fire suppression system or have a fire extinguisher nearby.

Impeller hazards. 

Do not place your hands or tools near the open inlet 

during operation for any reason. The powerful suction could easily cause 

accidental contact with the impeller, which will cause serious personal 

injury or damage to the machine. Always keep small animals and children 

away from open dust collection inlets.

Avoiding sparks. 

Do not allow steel or rocks to strike the impeller—this 

may produce sparks. Sparks can smolder in wood dust for a long time 

before a fire is detected. If you accidentally cut Into wood containing tramp 

metal (nails, staples, spikes, etc.), immediately turn off the dust collector, 

disconnect it from power, and wait for the impeller to stop—then empty the 

collection container into an approved airtight metal container. 

Operating location. 

To reduce respiratory exposure to fine dust, locate 

permanently installed dust collectors away from the working area, or in 

another room that is equipped with a smoke detector. Do not operate the 

dust collector in rainy or wet locations—exposure to water may create a 

shock hazard or decrease the life of the machine.

 

Static electricity. 

Plastic dust lines generate high amounts of static 

electricity as dust chips pass through them. Although rare, sparks caused 

by static electricity can cause explosions or fire. To reduce this risk, make 

sure all dust lines are thoroughly grounded by using a grounding wire.

 

Regular cleaning. 

Regularly check/empty the collection bags or drum to 

avoid the buildup of fine dust that can increase the risk of fire. Make sure 

to regularly clean the surrounding area where the machine is operated— 

excessive dust buildup on overhead lights, heaters, electrical panels, or 

other heat sources will increase the risk of fire.

Warning: If precautions are not heeded, it may result in minor injury and/or 

possible machine damage.

Warning: If precautions are not heeded, it may result in serious injury or 

possibly even death.

SAVE THESE INSTRUCTIONS.

Refer to them often and use them to instruct others.

3.4 

Motor Specifications

 

Your machine is wired for 400 volts, 50 HZ alternating current. Before 

connecting the machine to the power source, make sure the switch is in 

the “OFF” position.

3.5 Grounding Instructions

DANGER: THIS MACHINE MUST BE GROUNDED WHILE IN USE TO 

PROTECT THE OPERATOR FROM ELECTRIC SHOCK.

1. This appliance must be connected to a grounded metal, permanent 

wiring system; or an equipment-grounding conductor must be run with the 

circuit conductors and connected to the equipment-grounding terminal or 

lead on the appliance. 

The installer, such as a qualified electrician, cut (or bend over) and 

insulate the grounding conductor from a field wiring supply cable.

In the event of certain types of malfunctions or breakdowns, grounding 

provides a path of least resistance for electric current—in order to reduce 

the risk of electric shock. 

Improper connection of the equipment-grounding wire can result in a 

risk of electric shock. The wire with green insulation (with or without 

yellow stripes) is the equipment-grounding wire. If repair or replacement 

of the power cord or plug is necessary, do not connect the equipment-

grounding wire to a live (current carrying) terminal. Check with a qualified 

electrician or service personnel if you do not understand these grounding 

requirements, or if you are in doubt about whether the tool is properly

grounded. If you ever notice that a cord or plug is damaged or worn, 

disconnect it from power, and immediately replace it with a new one.

Electrical Circuit Requirements

You should use a separate electrical circuit for the Laguna PFlux. The 

circuit should be protected by a 20A circuit breaker with a tripping 

characteristic C. The power cable of the machine is factory fitted with 

400V industrial plug. The machine must be connected to an appropriate 

industrial socket or the machine can be connected to a terminal board and 

the wiring corresponding to the recommended fuse.

 

ATTENTION! WIRING MAY BE CARRIED OUT BY A QUALIFIED 

ELECTRICIAN ONLY.

Recommended circuit breaker: 20A, tripping characteristic C.

WARNING: MAKE SURE THE SOCKET IS EARTHED. IF YOU ARE 

NOT SURE, HAVE THE SOCKET CHECKED BY A QUALIFIED 

ELECTRICIAN.

4. Parts Description

4.1 Functional Description

High Frequency Remote Control Receiver and Manual Switch

HEPA Filter detection 

– will illuminate when filter cleans (automatic 

cleaning/override)

Full drum detection 

– when drum is full, buzzer* will constantly sound off 

and light will illuminate.

*When the drum is close to 70%-80% full; intermittent buzzing will occur; 

this is a normal state.

ON/OFF Switch 

– turns cyclone ON or OFF.

On board circuit breaker – Pops out if machine overloads. Press to 

reset.

Override 

– Press for (3) seconds to activate override cleaning while

 

the 

cyclone is ON. You can also activate this function by pressing the CLEAN 

button on the hand held remote for (3) seconds.

Receiver SET button 

– Used to program receiver.

ON/OFF Illuminate drum 

– controls the LED light on the drum lid to 

illuminate inside the drum for visuals of the dust level.

Hand held remote controller

*Used to match up a new hand held control with the remote switch

 

PROGRAMMING THE REMOTE CONTROL

1. Ensure the machine is switch ON before programming the remote 

control. 

2. Press the black set button on the bottom of the remote switch until you 

hear two beeps. 

3. Press the Remote set button on your hand held controller 

simultaneously with the black button until you hear three beeps to 

complete the set up.

 

 

 

 

 

 

Summary of Contents for LAGUNA PFlux3Tv2 2022

Page 1: ...istributor IGM n stroje a stroje s r o Ke Kopanin 560 252 67 Tuchom ice Czech Republic EU Phone 420 220 950 910 E mail sales igmtools com Website www igmtools com 2022 08 18 151 PFlux3Tv2 LAGUNA Cyclo...

Page 2: ...2 www igmtools com...

Page 3: ...the workshop If a procedure feels dangerous don t try it Figure out an alternative procedure that feels safer REMEMBER Your personal safety is your responsibility This machine was designed for certai...

Page 4: ...ace surrounding work area and non glare overhead lighting Keep the floor around the machine clean and free of scrap material oil and grease Keep visitors a safe distance from the work area Keep childr...

Page 5: ...This appliance must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding termi...

Page 6: ...ng or damaged parts to your dealer or distributor Prior to tool assembly and use read this manual thoroughly to familiarize yourself with proper assembly maintenance and safety procedures 5 2 General...

Page 7: ...r upright support panels to the unit using 6 5 16 3 4 hex bolts and 6 5 16 OD18 2t flat washers Step 8 Secure the 3 upright support reinforcement plates using 12 5 16 3 4 hex bolts and 12 5 16 OD18 2t...

Page 8: ...rotation shaft assembly into the HEPA filter from the top opening It will be easier to insert while holding it at a slanted angle The rotation shaft has a top and bottom end The top end has bolt hole...

Page 9: ...ot pedal bar and securing the U channel provided onto the foot pedal bar using 2 5 16 1 3 4 hex bolts 4 5 16 OD18 2t flat washers and 2 5 16 hex nuts from the inside out Follow the same steps for the...

Page 10: ...ach the crossbar Step 37 Assemble the Octagon drum Locate the drum base panel it does not matter which side faces inside and secure the 4 casters using 16 5 16 x 3 4 hex bolts 32 5 16 x 1 flat washers...

Page 11: ...1 2 and 24 Cap nut 3 16 to assemble the drum insert together Place the drum insert inside over the plastic bag in the Octagon drum Step 47 Lift the foot peddle bar Align the Octagon drum window to the...

Page 12: ...es of the Canister filter shield doors Connect the 4 flex hose from the cyclone to the 4 hook up on the canister end cap 2 While the cyclone is collecting the dust from inside the canister end cap use...

Page 13: ...all fasteners 4 Replace the motor and impeller 5 Check fan and cover replace as needed Dust cyclone does not adequately collect dust or chips poor performance Possible Cause 1 Canister end cap is ful...

Page 14: ...14 www igmtools com 8 POWER CONNECTIONS WIRING DIAGRAMS CONTROL PANEL POWER CONNECTIONS...

Page 15: ...15 www igmtools com AUTOCLEAN MOTOR SECONDARY JUNCTION BOX...

Page 16: ...16 www igmtools com 9 Parts breakdown Exploded Views 2021 10 14 X s I q...

Page 17: ...F22201 16D HEX NUT 5 16 4 16E PDCPF22201 16E DRUM CASTER 3 4 16U PDCPF22201 16U HEX BOLT 5 16 x 3 4 16 16F PDCPF22201 16F FLAT WASHER 5 16 xOD18x2t 32 16G PDCPF22201 16G HEX NUT 5 16 16 16H PDCPF22201...

Page 18: ...R ALARM 1 44 PDCPF22201 44 PHILIP HD BOLT M4 6mm 4 45 PDCPF22201 45 RUBBER HANDLE FOR DRUM INSERT 4 46 PDCPF22201 46 CONTROL PANDLE HANDLE 2 46A PDCPF22201 46A PHILIP HD BOLT M4 6mm 4 47 PDCPF22201 47...

Reviews: