www.igmtools.com
4
Operating instructions EN
www.igmtools.com
Do not use the machine if the ON-OFF switch does
not work correctly.
The use of any other accessories than recommended
by this manual be hazardous.
Make sure the cable is long enough and there is no
excessive tension or bend over the table.
Keep away from flammable or explosive materials.
3.3 Risks
Risk exists even when using the machine according
to the manual.
WATCH OUT! Heated glue may reach the
temperatures of 200°C. Do not touch any hot
parts.
The glue may contain harmful chemicals. Therefore,
ensure sufficient ventilation of your workplace.
3.4 Important notice
Make sure the machine has been off for at least 60
minutes before storing it in the portable case. That
way, the glue in the container will cool down to 60°C.
Use a piece of cloth to wipe any adhesive residues on
the machine.
The Edgebander is designed for interior work. Do
NOT use the machine outdoors!
If you want to prevent debris falling into the glue pot.
Put on the lid. If debris is already in the pot, remove
the glue, turn on the machine for approximately 3
minutes, the glue should come out easily now. Re-fill
with glue again.
1 Infeed tape guide
2 Temperature control
3 Set upof pressure of tape on application roller the
4 Main switch
5 Feed switch
6 Fuse
7 Outfeed roller
8 Support table locking lever
9 Support table with a handle
10 Glue pot cover
11 Regulation of amount of glue
12 Infeed roller pressure plate
4. SPECIFICATIONS OF THE MACHINE
4.1 Machine description
4
5
3
1
2
6
8
12
11
10
9
7