www.igm.cz
Návod na obsluhu CZ
27
www.igmtools.com
Operating Instruction EN
5.3 Power supply
WARNING:
Make sure the electrical connection
corresponds to the motor specification (see engine
cover.)
WARNING:
Make sure the switch is in the
„OFF“ position.
- Power cable for 230 V/50 Hz.
- Surge fuse 10 A.
Use a separate electrical circuit to connect the feeder.
The electrical connection parameters are listed on
the label on the back side of the motor. Make sure the
main switch is in the off position before connecting
the feeder to the power supply
. The voltage in the electric socket must be identical
to the parameters on the motor label. Make sure
all the cables, plugs and extensions are properly
contacted and are not damaged. Insufficient voltage
may cause damage to the motor.
Grounding
The feeder must be grounded to prevent electrical
shock. The power cord must be plugged into a
grounded socket. The plug must comply with local
standards for electrical safety.
When using an extension cord, make sure
it is grounded. Regularly check that the cable is not
damaged.
Damaged electric cord must be replaced
immediately.
If you are ever in doubt whether the power cord is
properly grounded, let a qualified electrician check
the cable.
5.4 Dust extraction
The feeder can be connected to dust extraction. The
extraction hoses can be connected directly to the
nozzle on the feeder, see pictures 11 and 12.
The outer diameter of the nozzle is 34 mm and the
inner one is 30,6 mm.
pic.10
pic.9
pic.11
pic.12
6. SET-UP AND ADJUSTMENT
6.1 Basic movements of the feeder
- Release the locking lever (A, pic.13), and rotate the
feeder to the desired position.
pic.13
- Release the locking lever (K, pic.14) and move the
feeder front or back by turning the lever (P).
pic.14