IMPORTANT INFORMATION 

 

The safety requirements are intended to protect consumers and ensure the long-term operation of the heat pump. 

By  purchasing  the  device,  users  confirm that they  undertake  to  use  it in  accordance  with  the manufacturer’s 

requirements and rules. Users involved in the operation of the heat pump must be familiar with and comply with 

all safety requirements. Failure to follow these operating instructions will void the manufacturer’s warranty and 

other  guarantees  and  obligations.  All  work  related  to  the  transport,  installation,  start-up,  activation  and 
maintenance of the heat pump must be carried out by qualified personnel, using suitable tools and test equipment. 
The work must be carried out in accordance with all safety requirements.  

The copyright of these operating instructions belongs to IGLU TECH UAB. 

Important! 

Only a qualified person may transport, connect, activate and maintain the heat pump. 

SAFETY INSTRUCTIONS 
 

Storage conditions 

The device must be stored in a 

vertical position only

, so that the compressor is always at the bottom. 

Installation and reconstruction 

Only a heating system maintenance company may be authorised to install or reconstruct the device. 

Customer recommendation  
Functional check. 

We recommend that you check the functioning of the device regularly, at least once a year*. 

Contact us for functionality check by e-mai

[email protected]

.

 

The extended warranty for the device is valid even 

in cases where preventive maintenance is not performed regularly. 

Liability and guarantees: 

The manufacturer undertakes to rectify the device free of charge within a period of two years, provided that 

the user has not violated the technical requirements and operating conditions specified in the user manual. 
The product has a 24-month warranty upon submission of the purchase documents. 
The product warranty is extended up to 60 months, under the following mandatory conditions: 

 

there is an additional cost of 5% of the pump price (payable immediately at the time of ordering); 

 

it is mandatory to connect the pump to our server for remote monitoring. 

If the heat pump does not operate in proper conditions or is not used properly, the present rules and requirements 
are not followed or the checks are not performed, the manufacturer shall not bear liability for the operation of the 
product. The heat pump operator must take precautions to prevent accidents and injuries to bystanders. The user 
is responsible for the safety of the heating system and compliance with environmental protection requirements. 

If a fault is detected, it is necessary to react promptly, within a reasonable time and as provided in this user manual, 
because failure to rectify a fault in a timely manner may result in other faults or damage.  

If the fault or other actions were carried out by an unqualified worker and in prejudice to the rules, the manufacturer 
cannot be held liable for the consequences and the warranty obligations may no longer apply. 

The  warranty  does  not  apply  to  normal  wear  and  tear,  external  damage  due  to  improper  maintenance  or 
negligence. 

 

Summary of Contents for INUIT 6 I

Page 1: ...USER MANUAL AIR TO WATER HEAT PUMPS IGLU INUIT...

Page 2: ...LU HOME MOBILE APPLICATION 8 INSTALLATION OF THE APPLICATION 8 LOGIN AND REGISTRATION 9 ADDING A NEW DEVICE 9 MAIN APPLICATION WINDOW 10 TEMPERATURES SETTINGS 11 SYSTEM ERROR AND FAILURE INDICATIONS 1...

Page 3: ...uries and enjoy the device for a long time CONCEPTS AND SYMBOLS Water heater boiler is a device that performs a very important function it prepares hot water Thermal disinfection thermal shock is a pr...

Page 4: ...ven in cases where preventive maintenance is not performed regularly Liability and guarantees The manufacturer undertakes to rectify the device free of charge within a period of two years provided tha...

Page 5: ...coolant leaks it poses risk to people and the environment therefore you must turn off the system make sure the installation room is well ventilated inform the manufacturer s customer service ATTENTION...

Page 6: ...performs three functions room heating cooling and hot water preparation Comfort at home can be controlled from anywhere in the world HOW DOES AIR TO WATER HEAT PUMP WORK An air to water heat pump wor...

Page 7: ...ly tilted not laid down The device can be stored at a temperature no lower than 10 C SELECTION OF THE INSTALLATION PLACE When choosing the place of installation of the heat pump mind that the heat pum...

Page 8: ...ly within a reasonable period of time red heat pump failure operation is stopped IGLU HOME MOBILE APPLICATION IGLU Inuit air to water heat pumps are controlled via the IGLU Home app It allows to contr...

Page 9: ...hen the login window opens enter the following information Window 3 E mail address Password You can log in by clicking the button If you forgot your password click Remind password ADDING A NEW DEVICE...

Page 10: ...coefficient of performance COP the ratio of thermal energy produced to electricity consumed to produce that heat IMPORTANT The IGLU Home application is supported by the latest versions of iOS and Andr...

Page 11: ...t bright triangle the heat pump will continue to operate but every effort should be made to rectify the fault In the event of a system fault dark triangle the heat pump operation will stop By clicking...

Page 12: ...e error disappears automatically Outdoor temperature sensor Temperature sensor or connection failure Contact customer service When the problem is resolved the error disappears automatically LP low pre...

Page 13: ...lem is resolved the error disappears automatically Valve configuration Incorrect EEV valve configuration Contact customer service FC not ready The frequency converter is not ready for operation E g oi...

Page 14: ...nt failure Fault in the power measurement chain of the internal circuit s circulating pump Contact customer service Compressor frequency converter failure Compressor frequency converter failure Detail...

Page 15: ...talled edit the information of the selected device add new device Clicking the Edit Selection button will take you to the device edit window Window 10 where you can update device address name of the d...

Page 16: ...the supplied heating water temperature of the returning heating water STATISTICS SECTION Clicking the Chart icon on the bottom bar will take you to the Statistics Home heating Window 15 where you will...

Page 17: ...In the device status window Window 2 you can turn the device off or on reset faults if any Navigation between windows in the control panel is performed using the and buttons In the water temperature w...

Page 18: ...pressor rated power Heating A7 W35 1 kW 1 22 1 87 2 59 3 76 Compressor rated power Heating A7 W35 5 kW 1 81 2 73 3 7 5 38 Compressor rated power Cooling A7 W35 6 kW 1 47 2 11 3 10 4 14 Max current wit...

Page 19: ...72 109 Power network connection values Electrical connections 1F 220 240V 50Hz 3F 400V 50Hz Compressor rated power Heating A7 W35 1 kW 1 22 1 87 2 59 3 76 Compressor rated power Heating A7 W35 5 kW 1...

Page 20: ...12 WTI IGLU INUIT 16 WTI INFORMATION CONCERNING THE EU DECLARATION OF CONFORMITY The IGLU INUIT heat pumps listed above meet the basic and other essential requirements of the European Union directives...

Reviews: