background image

en

23

User manual INNOVA

www.igloo.pl

Correspondence:

 

Stary Wiśnicz 289, 32-720 Nowy Wiśnicz

Poland

NIP: 868-000-50-40

Tel.: +48 14/662 19 10, fax: +48 14/662 19 12, e-mail: [email protected]

www.igloo.pl

Summary of Contents for INN100.110

Page 1: ...quipped in dynamic cooling automatic condensation evaporation and defrosting The display case is also equipped with an electronic thermostat which works optionally with the temperature registration module that enables registration and signalling high and low temperatures in the unit Display cases are adapted to connect in sequences and can be powered by an internal unit within the temperature rang...

Page 2: ...em 5 Internal surfaces with glass shelf 6 Suction DO NOT BLOCK the vents 7 Airflow DO NOT BLOCK the vents 8 Plinth block 9 Legs used to level the unit 10 Control panel thermostat switches Rys 2 Control panel 1 Main switch switches on off the unit 2 Light switch 3 Electromagnetic lock the front glass extension 4 Thermostat panel temperature controller the details of operating in Chapter 7 ...

Page 3: ...p clean 15 Bumbon Silicone element protecting glass components from moving and allowing for better grip Do not dama ge during operation and maintenance 16 Aluminium profile glass shelf support with backlight 17 Internal surfaces with glass shelf 18 Composite side glass with screen printing 19 Airflow DO NOT BLOCK the vents 2 3 Technical data Table 1 Technical data Type of the device INNOVA Rated v...

Page 4: ... with plug in socket with protecting pin according to PBUE Regulations concerning Electric Equipment Construction 3 2 Connection and actuation Unpack the device and remove the wooden platform from the basis Fig 3 p 15 The device should be placed on an even and on a sufficiently hard base and then level it with the help of levelling feet Remove the protection foil from the elements of the device f ...

Page 5: ... chapter 7 p 20 and 21 The basic aim of a thermostat is to control the cooling aggregate to obtain the set temperature within the device and maintain it within the determined temperature ranges The producer enters all settings of temperature regu lators required for normal functioning of the device Before primary actuation the user should control and possibly set the required temperature inside th...

Page 6: ...s out switch on the open close lock button on the control panel at the back of the unit and then press the release lock while slightly pressing against the wooden casing for the lock to let go To draw the front glass back in lightly press near the lock for the lock button to switch on To completely prevent from opening the front glass by unauthorized persons turn off the power of the electromagnet...

Page 7: ...ient temperature does not exceed 25ºC Enough time has passed for products to be cooled Ventilation holes of the device are not blocked This concerns the IGLOO thermostat thermostat displays C0 or C1 or C2 instead of displaying temperature This situation shall occur when one of temperature regulation sensors has been destroyed The following messages may be displayed in such case C0 temperature sens...

Page 8: ...essary clean the condenser Condenser ventilator is working properly Ambient temperature does not exceed 25ºC The device is working too loud Make sure that The device is standing stably and is properly levelled Furniture adjoining the device do not vibrate when the cooling aggregate compressor is working 6 2 Service IGLOO service telephone number 48 14 662 19 56 or 48 605 606 071 e mail serwis iglo...

Page 9: ...e decrease the temperature to the desired value The preview shall finish automatically after about 3 seconds Manual defrosting switch No 2 enables to initiate the defrosting cycle at any moment when the device is working re gardless of the automatic defrosting function the switch shall not operate when the temperature is higher than the final defrosting temperature The user should switch on switch...

Page 10: ...mperature inside the device is displayed decimal places displayed after the comma SETTING THE DESIRED TEMPERATURE press for 1 second leading value shall be displayed on the screen increase or decrease the leading value by means of and switches until the desired value shall be obtained press once again in order to confirm the new value of the setting point MANUAL INPUT OF THE DEFROSTING CYCLE Defro...

Page 11: ...en 23 User manual INNOVA www igloo pl Correspondence Stary Wiśnicz 289 32 720 Nowy Wiśnicz Poland NIP 868 000 50 40 Tel 48 14 662 19 10 fax 48 14 662 19 12 e mail info igloo pl www igloo pl ...

Reviews: