P/N 0503573_A

Note: Rev. A is first issue.

E3-XC

Data Sheet Set

P/N  0503573_A

NSF

®

Certified

March  2008

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

©2008 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES

4 Ft, 8 Ft & 12 Ft

A.

7W Standard

Fan Assembly 

(1)

0058698

Fan Motor, Evaporator 
(MO.4410102)

0142780

Fan Blade (FB.0142780)

7W Energy Efficient

Fan Assembly 

(1)

0477654

Fan Motor, Evaporator
(MO.4410545)

0142780

Fan Blade (FB.0142780)

6 Ft Only 

A.

4W Standard 

Fan Assembly  

(1)

0392457

Fan Motor, Evaporator
(MO.4410101)

0382383

Fan Blade (FB.4780617)

4W Energy Efficient

Fan Assembly 

(1)

0477653

Fan Motor, Evaporator
(MO.4410544)

0382383

Fan Blade (FB.4780617)

Item Part #

Description

Wiring Item #

T

HERMOSTATS

B. 0411744

Standard Non-adjustable

(2)

Defrost Thermostat 
(CT.0411744)

C. Optional Adjustable Refrigeration Thermostat (3)

L

AMPS AND

B

ALLASTS

D. Ballast, Electronic

(4)

0466234

2 lamps (BA.4480823)

0466235

3 lamps (BA.4480901)

0466236

4 lamps (BA.4481095)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

F. 0501213

Power Supply (EP.4481861)

(6)

G.

LED Fixture

(7)

Replace with like fixtures

Summary of Contents for IMPACT Elite E3-XC

Page 1: ...0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 6 Ft Only A 4W Standard Fan...

Page 2: ...5 8 752 D RH End of case to RH end of wireway 27 5 8 702 51 5 8 1311 57 1 4 1454 105 1 8 2670 E LH End of case to LH end of wireway 2 1 8 54 2 1 8 54 2 51 2 1 4 57 Waste Outlet F RH End of case to the...

Page 3: ...tion Temp F 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb E3 XC 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refri...

Page 4: ...Standard 0 70 0 82 1 20 1 70 120V 50Hz Standard 0 75 0 96 1 30 1 85 230V 60Hz Export 0 45 0 50 0 70 0 95 230V 50Hz Export 0 48 0 56 0 76 1 04 120V 60Hz Energy Efficient 0 39 0 44 0 58 0 77 230V 60Hz...

Page 5: ...44 m3 m ARI Total Display Area 3 Sq Ft Ft 3 30 ft2 ft 1 01 m2 m Shelf Area 4 Sq Ft Ft 7 07 ft2 ft 2 17 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft...

Page 6: ...st have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case GR...

Page 7: ...ponents in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W...

Page 8: ...illustration shows recommended shelf depth and shelf angle for the three locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illust...

Reviews: