background image

4 ft

6 ft

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

48 

1

/

8

(1222)

72 

1

/

(1832)

96 

1

/

4

(2445)

144 

3

/

8

(3667)

(Each end and insulated partition adds 1 in. (25 mm) to case line up.)

Maximum O/S dimension back to front 

(with bumper)

46 

1

/

2

(1181)

46 

1

/

2

(1181)

46 

1

/

2

(1181)

46 

1

/

2

(1181)

Back of case to front of front panel

34 

1

/

(876)

34 

1

/

(876)

34 

1

/

(876)

34 

1

/

(876)

Back of case to O/S edge of front skid rail

29 

3

/

(746)

29 

3

/

(746)

29 

3

/

(746)

29 

3

/

(746)

Width of skid rail

1

/

(114)

1

/

(114)

1

/

(114)

1

/

(114)

RH end of case to outside edge of external support

3

/

8

(34)

3

/

8

(34)

3

/

8

(34)

3

/

8

(34)

Distance between edges of 

external support and center support

NA

28 

1

/

(724)

40 

1

/

(1029)

40 

1

/

(1029)

Distance between edges of center supports

NA

NA

NA

44 (1118)

Stub-up area between front skid rail and front panel

3

/

(146)

3

/

(146)

3

/

(146)

3

/

(146)

Electrical Service                         

(Electrical Field Wiring connection point)

(B)

Length of electrical raceway

18 

3

/

8  

(467)

18 

3

/

8  

(467)

37 (940)

37 (940)

(C)

RH End of case to center of farthest knockout

36 

5

/

8  

(930)

60 

3

/

4  

(1543)

84 

3

/

(2153)

132 

3

/

(3372) 

Back of case to center of end knockout

29 

5

/

(752)

29 

5

/

(752)

29 

5

/

(752)

29 

5

/

(752)

(D)

RH End of case to RH end of wireway

27 

5

/

8  

(702)

51 

5

/

8  

(1311)

57 

1

/

4  

(1454)

105 

1

/

8  

(2670)

(E)

LH End of case to LH end of wireway

1

/

8  

(54)

1

/

8  

(54)

2 (51)

1

/

4  

(57)

Waste Outlet

(F)

RH End of case to the center of waste outlet

24 

1

/

(616)

24 

1

/

(616)

24 

1

/

(622)

72 

1

/

(1834)

LH End of case to the center of waste outlet

23 

7

/

(606)

47 

7

/

(1216)

71 

3

/

(1822)

72 

1

/

(1832)

Back O/S of case to center of waste outlet

27 

5

/

(702)

27 

5

/

(702)

27 

5

/

(702)

27 

5

/

(702)

Water Seal

Edge of water seal to center of waste outlet

4  (102)

4  (102)

4  (102)

4  (102)

Outside diameter of the drip pipe

1

/

(38)

1

/

(38)

1

/

(38)

1

/

(38)

NOTE: Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.

Refrigeration Outlet

Back of case to center of refrigeration outlet

30 

3

/

(781)

30 

3

/

(781)

30 

3

/

(781)

30 

3

/

(781)

RH end of case to center of refrigeration outlet

3

/

(213)

3

/

(213)

3

/

(213)

3

/

(213)

2 of 8

E3-XC   

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Engineering

Plan Views

Dimensions shown as

inches and (mm).

02-2008

34

 

1

/

2

 

(876)

8

 

3

/

8

 

 

(213)

Electrical Service

29

 

5

/

8

 

(752)

Waste Outlet

Front

C

L

A

C

D

B

F

E

27

 

5

/

8

 

(702)

30

 

3

/

4

 

(781)

46

 

1

/

2

 

(1181)

Water Seal

E3-XC

Delicatessen 

Precut & Packaged 

Produce

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Summary of Contents for IMPACT Elite E3-XC

Page 1: ...0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 6 Ft Only A 4W Standard Fan...

Page 2: ...5 8 752 D RH End of case to RH end of wireway 27 5 8 702 51 5 8 1311 57 1 4 1454 105 1 8 2670 E LH End of case to LH end of wireway 2 1 8 54 2 1 8 54 2 51 2 1 4 57 Waste Outlet F RH End of case to the...

Page 3: ...tion Temp F 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb E3 XC 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refri...

Page 4: ...Standard 0 70 0 82 1 20 1 70 120V 50Hz Standard 0 75 0 96 1 30 1 85 230V 60Hz Export 0 45 0 50 0 70 0 95 230V 50Hz Export 0 48 0 56 0 76 1 04 120V 60Hz Energy Efficient 0 39 0 44 0 58 0 77 230V 60Hz...

Page 5: ...44 m3 m ARI Total Display Area 3 Sq Ft Ft 3 30 ft2 ft 1 01 m2 m Shelf Area 4 Sq Ft Ft 7 07 ft2 ft 2 17 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft...

Page 6: ...st have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case GR...

Page 7: ...ponents in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W...

Page 8: ...illustration shows recommended shelf depth and shelf angle for the three locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illust...

Reviews: