Mains Plug Replacement
This fan must be earthed. Fit a 3A fuse in a 13A BS1363 plug.
Fit the green/yellow wire to E, the blue wire to N and the
brown wire to L. Fit the cable grip. Don’t use a non-rewireable
plug unless the fuse cover is fitted. If you remove the plug,
dispose of it.
CLEANING AND MAINTENANCE
Descaling
Regular descaling will prolong the life of the kettle.
1. Fill the appliance with three quarters of water and switch on using the” On” button. (Fig 5)
2. After the appliance has finished boiling and automatically switched off and unplug from the
electricity supply and add white vinegar to the boiled water to the “MAX” indicator.
3. Leave the water/vinegar solution overnight.
4. Empty the kettle and thoroughly rinse any excess solution out.
5. Fill the kettle with clean water and boil. (see Operating Instructions)
6. Unplug and empty the appliance again and repeat instruction 5 until all scale has been removed.
7. Clean the exterior of the appliance with a clean damp cloth and then dry with a clean cloth.
TROUBLE SHOOTING
Please refer to the trouble shooting guide when experiencing an issue with your heater. If you still cannot
determine the fault then please call our Customer Services number 01473 271272
Problem
Possible Cause
Solution
The kettle does
not work.
1. Not properly plugged into the
mains wall socket.
2. No electricity in the mains
wall socket.
3. On/Off switch not turned on.
4. Safety cut-out activated.
1. Plug in firmly
2. Check fuse or breaker.
3. Push on/off switch to on.
4. Fill the kettle and allow to cool for
a few minutes.
Large build up of scale in the
kettle.
The kettle cuts out
before it boils.
Use a descaling agent to clean
the kettle.
Kettle scales up
quickly.
You live in a hard water area.
Regularly de-scale your kettle