ZZ0814 ZZ0815 ZZ0816 ZZ0817
9
6 Installation
Mount ZZ0814 (detection of loading direction via 3D sensor O3D)
Fig. 1: Mounting the units with 3D sensor (7) on a gate
1
ANT860
RFID read/write head UHF (antenna)
2
ANT860
RFID read/write head UHF (antenna)
3
ANT860
RFID read/write head UHF (antenna)
4
ANT860
RFID read/write head UHF (antenna)
5
ZZ1124
edgeController
6
DV2510
5-segment light tower
7
O3D354
3D sensor O3D
Mounting the units:
u
Mount ANT860 (1) and (3) at a height of approx. 1 m.
u
Mount ANT860 (2) and (4) at a height of approx. 2 m.
u
Mount DV2510 (6) clearly visible above the gate.
u
Mount O3D354 (7) in ca central position above the gate at a height of approx. 4 m.
w
The O3D354 must point vertically downwards.
u
Mount ZZ1124 (5) clearly visible near the gate.
w
The units are installed.
Mounting ZZ0816 (detection of the loading direction via 2x light barrier)
Fig. 2: Mounting the units with light barrier (7) and (8) on a gate
1
ANT860
RFID read/write head UHF (antenna)
2
ANT860
RFID read/write head UHF (antenna)
3
ANT860
RFID read/write head UHF (antenna)
4
ANT860
RFID read/write head UHF (antenna)
5
ZZ1124
edgeController
6
DV2510
5-segment light tower
7
OGP700
retro-reflective laser sensor
8
OGP700
retro-reflective laser sensor
Mounting the units:
u
Mount ANT860 (1) and (3) at a height of approx. 1 m.
u
Mount ANT860 (2) and (4) at a height of approx. 2 m.