background image

4

6  Settings

The unit and the parameters are set via the teach button 

(→ 6.1)

.

6.1  teach button
6.1.1  Start programming mode

 

Press the teach button for 2 s...6 s.

 

>

Yellow status LEDs 1/2 flash (1 Hz), the unit is in the programming mode.

If programming has not been completed successfully, the unit returns to the 

previous setting.

6.1.2  Set output response

 

Start programming mode (

→ 6.1.1).

 

► Position the object in P1 (Fig. 1 or 2).

 

Press the teach button for 1 s.

 

>

Yellow status LEDs 1/2  flash (2.5 Hz), P1 setting is completed.

 

► Position the object in P2 (Fig. 1 or 2).

 

Press the teach button for 1 s.

 

>

Yellow status LEDs 1/2 flash briefly (4 Hz), P2 setting is completed.

6.1.3  Invert output response

 

Press the teach button for > 6 s.

 

>

Yellow status LEDs 1/2 flash (> 10 Hz).

 

>

Yellow status LEDs 1/2 flash briefly (> 4 Hz).

 

> Output function is inverted.

6.1.4  Restore factory setting

 

Align the unit so that no echo is received.

 

>

Green echo LED off.

 

Start programming mode (

→ 6.1.1).

 

Press the teach button for 1 s.

 

>

Yellow status LEDs 1/2 flash briefly (4 Hz), factory setting is restored.