1  Safety instructions

•  The device described is a subcomponent for integration into a system.

 - The manufacturer of the system is responsible for the safety of the system.
 - The system manufacturer undertakes to perform a risk assessment and to 

create a documentation in accordance with legal and normative requirements 
to be provided to the operator and user of the system. This documentation 
must contain all necessary information and safety instructions for the operator, 
the user and, if applicable, for any service personnel authorised by the 
manufacturer of the system.

•  Read this document before setting up the product and keep it during the entire 

service life.

•  The product must be suitable for the corresponding applications and 

environmental conditions without any restrictions.

•  Only use the product for its intended purpose (→ Functions and features).
•  Only use the product for permissible media (→ Technical data). 
•  If the operating instructions or the technical data are not adhered to, personal 

injury and/or damage to property may occur.  

•  The manufacturer assumes no liability or warranty for any consequences 

caused by tampering with the product or incorrect use by the operator.

•  Installation, electrical connection, set-up, operation and maintenance of the unit 

must be carried out by qualified personnel authorised by the machine operator.

•  Protect units and cables against damage.

2  Functions and features

The unit detects the medium temperature and converts it into an analogue output 
signal.

Summary of Contents for TA3 Series

Page 1: ...Installation Instructions Temperature transmitters TA3xxx TA4xxx TA5xxx TU3xxx TU4xxx TU5xxx 80288981 00 09 2019 UK ...

Page 2: ...entire service life The product must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose Functions and features Only use the product for permissible media Technical data If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufact...

Page 3: ...low the measuring range 4 3 7 mA MAW MEW 20 20 6 4 3 7 T C F I mA Fig 2 Voltage output TUxxxx In the measuring range the output signal is between 0 5 und 4 5 V If the temperature is above or below the measuring range the analogue output behaves as follows Temperature above the measuring range 4 5 5V Temperature below the measuring range 0 5 0 V MAW MEW 4 5 5 0 5 T C F U V T Temperature MAW initial...

Page 4: ... Tightening torque for units with M10x1 20 25 Nm 5 Electrical connection The unit must be connected by a qualified electrician The national and international regulations for the installation of electrical equipment must be adhered to Voltage supply to EN 50178 SELV PELV Disconnect power Connect the unit as follows TA3xxx 2 1 L BN 1 WH 2 OUT M12 OUT analogue output 4 20 mA TA4xxx A C B DEUTSCH DT04...

Page 5: ...P OUT analogue output 0 5 4 5 V TU47xx A C B A C B OUT L L L DEUTSCH DT04 3P OUT sortie analogique 0 5 4 5 V TU5xxx 2 1 3 1 2 3 OUT L L AMP Superseal OUT analogue output 0 5 4 5 V Colours to DIN EN 60947 5 2 BK black BN brown BU blue WH white 6 Operation After power on the unit is in the Run mode normal operating mode 7 Technical data Technical data and scale drawing at www ifm com ...

Reviews: