5
UK
3.1 Applications
Type of pressure: relative pressure
Order no.
Measuring range
Permissible
overload
pressure *
)
Bursting
pressure
MPa
kPa
MPa
kPa
MPa
kPa
Pressure sensors with G¼ internal thread
PN7010
0���40
-
80
-
170
-
PN7011
0���25
-
50
-
110
-
PN7032**
0���10
-
30
-
65
-
PN7033**
0���2,5
-
15
-
35
-
PN7034**
-0,1���1
-
7,5
-
15
-
PN7036
-
0���250
-
2000
-
5000
PN7039
-
-100���100
-
1000
-
3000
*
)
With static overload pressure or max� 100 million pressure cycles�
**
)
Use devices with a measuring range >2,5 MPa for gas applications >25 MPa!
Avoid static and dynamic overpressure exceeding the specified overload
pressure by taking appropriate measures� The indicated bursting pressure
must not be exceeded�
Even if the bursting pressure is exceeded only for a short time, the unit
may be destroyed� NOTE: Risk of injury!
The units are vacuum resistant�
Pressure Equipment Directive (PED):
The units comply with the Pressure Equipment Directive and are designed
and manufactured for group 2 fluids in accordance with the sound
engineering practice� Use of group 1 fluids on request!