background image

5

UK

Setting of the maximum sensitivity

Go into the programming mode (step 1).
Align the unit so that no light is reflected.
Press the setting button twice (see steps 2 and 3).

Setting the output function

You can change the output function by means of the setting button:

light-on mode (output switched, LED yellow = ON, if no object is present),
dark-on mode (output switched, LED yellow = ON, if object is present).

State when delivered: dark-on mode.

Press for 10s.

The yellow and green LEDs flash 
alternately;
after 10s the LEDs go out, the output 
function has been changed.

Operation

Check the safe functioning of the diffuse reflection sensor. Display by LEDs.

LED green lights

Unit is ready for operation.

LED yellow lights

Output is switched.

LEDs yellow flashes

2 Hz: Output short-circuited,
1 Hz: Internal malfunction,
(output is not switched).

Maintenance

Keep the lens of the sensor free from soiling. For cleaning do not use any solvents 
or cleaning agents which could damage the plastic lenses.




Reviews: