3
UK
NB: Commissioning
The retro-reflective sensor is supplied ready to operate (plug and play) set at the
max. sensing range. This is sufficient if the retro-reflective sensor can operate
with maximum excess gain (highest contrast). The following setting procedures
should only be necessary in less straightforward applications, for example if partly
transparent objects must be detected.
Setting of the sensitivity with stationary objects
1
Activate the programming mode of the unit.
Press for about 2s until the LEDs flash.
Yellow and green LEDs flash alternately.
The unit is in the programming mode.
2
Set the sensitivity with object.
Press once.
The yellow and green LEDs go out for approx. 1s, then flash again alternately.
3
Set the sensitivity without object.
Press once.
The yellow and green LEDs go out for approx. 1s, then the green LED is on.
The unit is in the operating mode.
You can also proceed in reverse order: first setting without the object, then with the object.