Modify the switching threshold
►
Press [OUT off] to reduce the switching threshold�
►
Press [OUT on] to increase the switching threshold�
-Fast forward by keeping the button pressed�
3
Exit setting
►
Press [OUT on] + [OUT off] simultaneously�
> The unit changes to the normal operating mode�
4
► Check the safe switching function. If necessary, repeat the setting (→ step 1).
Timeout
If no button is pressed for 15 min during the setting procedure, the unit
changes to the normal operating mode with unchanged values�
6.3 Setting of maximum sensitivity
►
Align the fibre optics so that no light is received�
The sensor is to switch when light is received
►
First press [OUT on], then [OUT off]�
The sensor is to switch when no light is received
►
First press [OUT off], then [OUT on]�