8

7.1.4  Programming unsuccessful

 

> The LED flashes quickly, 8 Hz�
•  Insufficient difference in measurements�
• 

Max. programming time (15 min.) exceeded.

7.1.5  Electronic lock

Lock or unlock the buttons

 

Press [OUT ON] and [OUT OFF] simultaneously for 10 s�

 

> Acknowledgement is indicated by a brief change of the LED switching status�

7.2  Setting via IO-Link

This unit has an IO-Link communication interface which enables direct access to 

process and diagnostic data� In addition it is possible to set the parameters of the 

unit while it is in operation� Operation of the unit via an IO-Link interface requires 

an IO-Link master�
With a PC, suitable IO-Link software and an IO-Link adapter cable communication 

is possible when the system is not in operation�
The IODDs necessary for the configuration of the unit, detailed information about 

process data structure, diagnostic information, parameter addresses and the 

necessary information about the required IO-Link hardware and software can be 

found at www�ifm�com�

7.2.1  Adjustable parameters

Among others, the following parameters can be set via IO-Link�

A table of all adjustable parameters can be found at www�ifm�com/de/io-

link�

Parameter 

name

Values

Description

Default

SSC1 Param�

SP1

1 ��� 100 Setting switch point in step increment "1"� 

After a teach process the resulting value is 

displayed�

100

Teach SP1 TP1 

1� Part of the teach sequence to set switch 

point SP1 by teach on object�  Both parts of 

the teach sequence for TP1 and TP2 (TP = 

teach point) have to be carried out.

N� A�

Summary of Contents for O6P7 Series

Page 1: ...Operating instructions Retro reflective sensor O6P7xx 706459 00 04 2019 UK...

Page 2: ...7 7 1 2 The sensor is not to switch when the object is detected 7 7 1 3 Setting the maximum sensitivity 7 7 1 4 Programming unsuccessful 8 7 1 5 Electronic lock 8 7 2 Setting via IO Link 8 7 2 1 Adju...

Page 3: ...ata are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use...

Page 4: ...the retro reflective sensor detects objects and materials without contact and indicates their presence by a switching signal 4 Installation Fit the prismatic reflector or the reflective tape behind t...

Page 5: ...tching output active 4 OUT ON button 5 1 Stability indication The green LED is on when the supply voltage is applied and the sensor signal is stable Stable signal Switch point Stable signal Light on m...

Page 6: ...e voltage supply to EN 50178 Disconnect power Connect the unit as follows 6 1 PNP M12 pigtail connector Cable BK black BN brown BU blue Colours to DIN EN 60947 5 2 M8 connector 3 pole M8 connector 4 p...

Page 7: ...The yellow LED goes out Pro gramming is completed 7 1 2 The sensor is not to switch when the object is detected Position the object see Fig 1 and press OUT OFF for 2s Remove the object see Fig 2 and p...

Page 8: ...n IO Link adapter cable communication is possible when the system is not in operation The IODDs necessary for the configuration of the unit detailed information about process data structure diagnostic...

Page 9: ...function off AUTo anti crosstalk function on OFF SSC1 Config Logic High active Low active Switch point logic status for detected object High light on mode normally open Low dark on mode normally clos...

Page 10: ...ic reflector or reflective tape Fig 2 Press Teach SP1 TP2 in the LR DEVICE software Either the object can be set first and then the prismatic reflector reflective tape or the other way around Fig 1 Fi...

Page 11: ...witched the yellow LED is on when no object is detected 9 Maintenance repair disposal Keep the lens of the sensor free from soiling For cleaning do not use any solvents or cleaning agents which could...

Reviews: