![IFM O6P7 Series Operating Instructions Manual Download Page 10](http://html1.mh-extra.com/html/ifm/o6p7-series/o6p7-series_operating-instructions-manual_4040501010.webp)
10
7.2.2 Set sensitivity with prismatic reflector / reflective tape and object
►
Start the LR DEVICE software�
► Align the retro-reflective sensor to the object (Fig. 1).
►
Press [Teach SP1 TP1] in the LR DEVICE software�
►
Align the retro-reflective sensor to the prismatic reflector or reflective tape
(Fig. 2).
►
Press [Teach SP1 TP2] in the LR DEVICE software�
Either the object can be set first and then the prismatic reflector / reflective
tape, or the other way around�
Fig� 1:
Fig� 2:
TP1
TP2
TP1: teach point 1
TP2: teach point 2
7.2.3 Setting the maximum sensitivity
►
Start the LR DEVICE software�
►
Align the sensor so that no light is reflected�
►
Press [Teach SP1 TP1] in the LR DEVICE software�
►
Press [Teach SP1 TP2] in the LR DEVICE software�