7.1.2 The sensor is not to switch when the object is detected
► Position the object (see Fig. 1) and press [OUT OFF] for > 2s.
► Remove the object (see Fig. 2) and press [OUT ON].
The settings can also be carried out first without object and then with
object�
7.1.3 Setting the maximum sensitivity
►
Align the object so that no light is received�
1. The sensor is to switch when the object is detected
►
Press [OUT ON] for > 2 s, then [OUT OFF]�
2. The sensor is not to switch when the object is detected
►
Press [OUT OFF] for > 2 s, then [OUT ON]�
7.1.4 Programming unsuccessful
> The LED flashes quickly, 8 Hz�
• Insufficient difference in measurements�
•
Max. programming time (15 min.) exceeded.
7.1.5 Electronic lock
Lock or unlock the buttons
►
Press [OUT ON] and [OUT OFF] simultaneously for 10 s�
> Acknowledgement is indicated by a brief change of the LED switching status�
7.2 Setting via IO-Link
This unit has an IO-Link communication interface which enables direct access to
process and diagnostic data� In addition it is possible to set the parameters of the
unit while it is in operation� Operation of the unit via an IO-Link interface requires
an IO-Link master�
With a PC, suitable IO-Link software and an IO-Link adapter cable communication
is possible when the system is not in operation�
The IODDs necessary for the configuration of the unit, detailed information about
process data structure, diagnostic information, parameter addresses and the
necessary information about the required IO-Link hardware and software can be
found at www�ifm�com�