![IFM O2D50 Series Operating Instructions Manual Download Page 20](http://html1.mh-extra.com/html/ifm/o2d50-series/o2d50-series_operating-instructions-manual_4011134020.webp)
O2D50x O2D52x
Object recognition sensor
20
8 Operating and display elements
3
4
5
6
2
7
1
Fig. 10: LEDs and button
1:
Multi-function LED (green)
2:
Multi-function LED (yellow)
3:
Ethernet LED (green)
4:
Power LED (green)
5:
OUT3-LED (yellow)
6:
OUT4-LED (yellow)
7:
Multi-function key
8.1 Signal indications
Multi-function LED (green)
Multi-function LED (yellow)
Description
On
---
Alignment mode active
On
flashes at 1 Hz
Set-up mode active
flashes at 2 Hz
---
Configuration is saved
on for 2 s
---
Configuration successfully saved
flashes at 8 Hz
flashes at 8 Hz
Active mode for configuration transfer from ifm storage
device via multi-function key (
---
flashes at 8 Hz
Error: lock button is active
---
flashes at 8 Hz
Error: configuration failed
Tab. 5: Multifunction LED (green, yellow)
Ethernet LED
Power LED
OUT3-LED
OUT4-LED
Description
off
On
off
off
Unit is ready for operation.
---
flashes at 0.5 Hz
---
---
No parameters set or parameter setting was
not loaded into the unit.
On
Off
---
flashes 2x at 0.5 Hz
---
---
Unit is in parameter setting mode.
On
Off
---
On
On
---
OUT3 is switched.
---
On
flashes at 8 Hz
---
OUT3 has a short circuit.
---
On
---
On
OUT4 is switched.
---
On
---
flashes at 8 Hz
OUT4 has a short circuit.
On
On
---
---
Unit is ready for operation, Ethernet is con-
nected.
flashes
On
---
---
Ethernet transmitting data.
---
off
flashes at 8 Hz
flashes at 8 Hz
Unit signals internal error.
---
off
flashes at 2 Hz
flashes at 2 Hz
Unit signals correctable error. The error infor-
mation can be read via Ethernet.
---
Running light
⇒
Unit booting.
---
Running light
⇐
Unit carrying out firmware update.
off
off
off
off
No voltage or voltage too low.
Tab. 6: Ethernet, power, OUT3-, OUT4-LED
--- means undefined state