Object recognition sensor
O2D50x O2D52x
15
5.3 Mounting with dome illumination
2
3
4
1
5
Fig. 8: Installation using the mounting set E2D501
1:
M4 screws
2:
threaded M4 holes (depth 7 mm)
3:
bracket
4:
clamp
5:
dome illumination
u
Fasten the bracket to the threaded M4 holes of the unit using two M4 screws. Tightening torque
max. 2.1 Nm.
u
Fasten the bracket to the dome illumination using four screws.
u
Fix the clamp to the bracket.