Measuring

range

[mm]

Repeatability* [mm]

Accuracy* [mm]

white (90%

remission)

grey (18%
remission)

white (90%

remission)

grey (18%
remission)

200...1000

10 (±5)

15 (±7.5)

±15

±18

1000...2000

11 (±5.5)

20 (±10)

±15

±20

2000...4000

35 (±17.5)

45 (±22.5)

±25

±32

4000...6000

55 (±27.5)

80 (±40)

±35

±50

6000...10,000

120 (±60)

±70

* The values specified for repeatability and accuracy refer to a sampling

frequency of 50 Hz. At a lower sampling frequency, which is adjustable
on the unit, these values will be lower. View the calculation tool at
www.ifmefector.com/ifmus/web/pmd_5.htm

Distance to target 

(shown on sensor display)

[mm]

200...1000

1,000...2000

2,000...4000

4,000...6000

6,000...10,000

Minimum distance from

target to background

[mm]

38

50

113

200

300

For background suppression applications

The following chart shows the minimum distance required
between target and background