Binary level sensor

LMT0xA

9

The variable clamp fitting (accessory) allows variable installation of the unit types LMT03A and
LMT04A in height/installation depth. This enables, for example, a high-precision adjustment of
the response level. Moreover, these types can be uncoupled thermally from the process by
means of the variable clamp fitting (recessed installation of the sensor electronics). This also
allows applications with higher process temperature and/or with the risk of heat accumulation
(e.g. tank insulation).

5.3 Notes on the use according to EHEDG

The unit is suited for CIP (cleaning in process) when installed correctly.

u

Observe the application limits (temperature and material resistance) according to the data
sheet.

u

Ensure that the installation of the unit in the system complies with EHEDG guidelines.

u

Use self-draining installation.

u

Only use process adapters permitted according to EHEDG with special seals required by the
EHEDG position paper.

The gasket of the system interface must not be in contact with the sealing point of the sensor.

u

In case of structures in a tank, the installation must be flush mount. If not possible then direct water
jet cleaning and cleaning of dead spaces must be possible.

u

Leakage ports must be clearly visible and must be installed facing downwards for vertical pipes.

L

d

D

1

1:

Leakage port

u

To avoid dead space adhere to the dimensions:
L < (D - d).

5.4 Notes on the regulation (EC) 1935/2004

The following components of the product are designed for permanent contact with food according to
the regulation (EC) 1935/2004:

– Sensor tip made of PEEK

– Sealing ring made of PEEK

– Sealing ring made of FKM (LMT03A / LMT04A)

5.5 Installation procedure

The unit is installed by means of an adapter:

GB

Summary of Contents for LMT0 A Series

Page 1: ...Operating instructions Binary level sensor LMT0xA 80301827 00 03 2021 GB...

Page 2: ...9 5 5 1 Installation LMT01A hygiene compliant 10 5 5 2 Installation LMT03A and LMT04A 10 6 Electrical connection 12 7 Parameter setting 13 7 1 IO Link communication interface 13 7 2 Parameter setting...

Page 3: ...unit packaging or at www ifm com 1 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfun...

Page 4: ...the EU directive 94 9 EC annex VIII ATEX group II equipment category 3D 3G If no operating instructions Ex protection related part or EC declaration of conformity are supplied with this product in th...

Page 5: ...253 mm G1 2 1 Sensitivity adjustable Parameter setting 2 Probe length measured from conical sealing edge Technical data 3 2 Restriction of the application area Not suitable for abrasive media e g quar...

Page 6: ...tip generates an electrical field that is influenced by the level The nature of the medium as well as build up or foam have different electrical properties that are used for the evaluation 4 2 Other f...

Page 7: ...Installation preferably in closed metal tanks or pipes The sensor must be in electrical contact with the metal process connection When installed in plastic tanks there may be deterioration caused by...

Page 8: ...ive and viscous media and media prone to sedimentation or build up the installation positions 1 are only suitable to some extent Residues might be detected as level 5 2 2 Unit types with long probe In...

Page 9: ...unit in the system complies with EHEDG guidelines u Use self draining installation u Only use process adapters permitted according to EHEDG with special seals required by the EHEDG position paper The...

Page 10: ...he thread using a suitable lubricating paste which has been approved for this application u Screw the sensor into the respective process connection and tighten it Maximum tightening torque 20 25 Nm u...

Page 11: ...t hygienic zero leak using PEEK gasket 3 4 1 3 4 3 Fig 8 LMT seal PEEK 1 Green flat seal 3 PEEK sealing ring beige accessory E43323 4 Black flat seal E43323 u If needed replace green flat seal 1 on de...

Page 12: ...Normal operation factory setting L 1 BN 2 WH 4 BK 3 BU OUT1 OUT2 L 4 3 2 1 Teach operation L 1 BN 2 WH 4 BK 3 BU IN OUT2 L 4 3 2 1 Pin Core colours 1 BN brown 2 WH white 3 BU blue 4 BK black OUT1 PNP...

Page 13: ...nfiguration of the unit detailed information about process data structure diagnostic information parameter addresses and the necessary information about the required IO Link hardware and software can...

Page 14: ...nimum hysteresis 2 Reference values Aqueous water based media SPx 62 rPx 54 Media with low water content SPx 35 rPx 29 Oils fats powders SPx 8 rPx 5 ou1 ou2 ou1 ou2 output function for OUT1 OUT2 Hno h...

Page 15: ...he teach input The teach input must be activated u This requires previous configuration via IO Link parameter ou2 tch Output OUT2 must be configured as hysteresis function Hnc or Hno If the window fun...

Page 16: ...ellow with 8 Hz w The unit returns to the operating mode with unchanged settings Possible faults Time error teach time too long too short Internal sensor signal not clear Wrong output function Paramet...

Page 17: ...lure OFF OFF Teach operation Full adjustment via the teach input and Changing the output function Fault during the teach operation LEDs are flashing green yellow with 8Hz 1 according to the level The...

Page 18: ...tant to ingress and without dead space u It is not possible to repair the unit u In case of return shipment ensure that the unit is free from soiling especially from dangerous and toxic substances u F...

Page 19: ...y setting LMT0xA User settings SP1 8 rp1 5 ou1 Hno SP2 8 rp2 5 ou2 Hnc FOU1 OFF FOU2 OFF dS1 0 0 dS2 0 0 dr1 0 0 dr2 0 0 P n PnP dFo 0 0 Percentage values refer to the process value Parameter setting...

Reviews: