Programming Manual BasicController relay CR0431 v03.03.00
05 / 2018
ifm function elements
ifm function elements for the device CR0431
GET_IDENTITY
8166
Unit type = function block (FB)
Unit is contained in the library
ifm_CR0431_Vxxyyzz.LIB
Symbol in CODESYS:
>
Description
15411
GET_IDENTITY reads the identification stored in the device (has previously been saved by means of
SET_IDENTITY
(
>
Parameters of the inputs
8167
Parameter
Data type
Description
ENABLE
BOOL
TRUE:
execute this function element
FALSE:
unit is not executed
> Function block inputs are not active
> Function block outputs are not specified
>
Parameters of the outputs
8168
Parameter
Data type
Description
APP_IDENT
STRING(80)
identifier of the application
as a string of max. 80 characters, e.g.: "Crane1704"
RESULT
BYTE
feedback of the function block
(possible messages → following table)
Possible results for RESULT:
Value
dec | hex
Description
0
00
FB is inactive
1
01
FB execution completed without error
– data is valid
155
9B
value could not be read