7.2
Connecting switching outputs
59414
Optional: Connect the switching outputs DQ1 (Pin 2 ) and DQ2 (Pin 4) of the "power" port with
actuators.
A digital switching output can switch max. 200 mA.
>
7.3
Connecting the device
59415
The device has a current rating of 2000 mA.
► Connect the device via an M12 socket to the voltage supply (24 V DC (18...30 V SELV)).
▪
Tightening torque: 0,6...0,8 Nm.
▪
Recommended maximum cable length: 25 m
► To connect the device, use M12 connectors with at least protection rating IP 65 (→
Accessories
(
)).
Wiring:
1:
+ 24 V DC (US)
2:
DQ (OUT2)
3:
GND (US)
4:
DQ (OUT1)