Operating instructions FX460
25
AVERAGE FILTER
Optional averaging or filter function to avoid display fluctuations with unstable frequencies� With the
EXPONENTIAL FILTER setting the device uses an exponential function� The time constant T (63 %)
corresponds to the number of the sampling cycles�
Example: With SAMPLING TIME = 0�1 s and EXPONENTIAL FILTER 2 (exponential filter, T (63 %) = 2 x
sampling time) 63 % of the jump height are reached after 0�2 s�
OFF
No averaging
CYCLE FILTER 2
Free-flowing averaging with 2 cycles
CYCLE FILTER 4
Free-flowing averaging with 4 cycles
CYCLE FILTER 8
Free-flowing averaging with 8 cycles
CYCLE FILTER 16
Free-flowing averaging with 16 cycles
EXPONENTIAL FILTER 2
Exponential filter, T (63 %) = 2 x sampling time
EXPONENTIAL FILTER 4
Exponential filter, T (63 %) = 4 x sampling time
EXPONENTIAL FILTER 8
Exponential filter, T (63 %) = 8 x sampling time
EXPONENTIAL FILTER 16
Exponential filter, T (63 %) = 16 x sampling time
9.5 Timer mode
In this menu, operation can be defined as timer / stop watch� Depending on the
parameter setting, only input A or input A and B are active� This menu is only
displayed if the corresponding OPERATIONAL MODE is selected in the GENERAL
MENU�
TIME BASE
Selection of the time base / resolution required for the measurement
1/1000 SEC
Milliseconds
1/100 SEC
1/100 seconds
1/10 SEC
1/10 seconds
SECONDS
Seconds
MIN�00
Minutes and 1/100 minutes
MIN�0
Minutes and 1/10 minutes
MIN:SEC
minutes : seconds (max� 999999:59)
MIN:SEC:00
minutes : seconds : 1/100 seconds (max� 9999:59:99)
H:M:S
Hours: minutes : seconds (max� 9999:59:59)
H:M
Hours: minutes (max� 9999:59)